A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Counterfeit homeopathic medicinal products: syrups. A simple and rapid LC-ESI-MS method to detect preservatives not declared in label. | LitMetric

Counterfeit homeopathic medicinal products: syrups. A simple and rapid LC-ESI-MS method to detect preservatives not declared in label.

J Pharm Biomed Anal

Dipartimento del Farmaco, Istituto Superiore di Sanità, Viale Regina Elena 299, 00161 Rome, Italy.

Published: August 2008

A rapid and simple LC-ESI-MS method for the simultaneous detection and quantitation of six preservatives in homeopathic syrups has been developed. Counterfeit homeopathic syrups are suspected to contain preservatives that are not declared in label. For this reason a method to ascertain the absence of sorbic and benzoic acids, methyl-, ethyl-, propyl- and butyl-parabens, as the most frequently utilised preservatives, has been developed. Analytes were eluted with a linear gradient of acetonitrile-5mM ammonium acetate in 12 min using 2,4-dichlorobenzylalchol as Internal Standard. The HPLC separation was performed on an Eclipse XDB-C18 (2.1 mm x 50 mm-5 microm) column and the ESI-MS detection was performed in negative ion mode. Linearity of the method was studied in the range of 2 pg to 10 ng injected and correlation coefficients r2 > or =0.9992 were obtained. LOD ranged from 0.04 to 0.4 ng mL(-1).

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jpba.2008.03.017DOI Listing

Publication Analysis

Top Keywords

counterfeit homeopathic
8
lc-esi-ms method
8
preservatives declared
8
declared label
8
homeopathic syrups
8
homeopathic medicinal
4
medicinal products
4
products syrups
4
syrups simple
4
simple rapid
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!