Dust exposure in indoor climbing halls.

J Environ Monit

Institute of Applied Geosciences, Technical University Darmstadt, Schnittspahnstr. 9, Darmstadt, 64287, Germany.

Published: May 2008

The use of hydrated magnesium carbonate hydroxide (magnesia alba) for drying the hands is a strong source for particulate matter in indoor climbing halls. Particle mass concentrations (PM10, PM2.5 and PM1) were measured with an optical particle counter in 9 indoor climbing halls and in 5 sports halls. Mean values for PM10 in indoor climbing halls are generally on the order of 200-500 microg m(-3). For periods of high activity, which last for several hours, PM10 values between 1000 and 4000 microg m(-3) were observed. PM(2.5) is on the order of 30-100 microg m(-3) and reaches values up to 500 microg m(-3), if many users are present. In sports halls, the mass concentrations are usually much lower (PM10 < 100 microg m(-3), PM2.5 < or = 20 microg m(-3)). However, for apparatus gymnastics (a sport in which magnesia alba is also used) similar dust concentrations as for indoor climbing were observed. The size distribution and the total particle number concentration (3.7 nm-10 microm electrical mobility diameter) were determined in one climbing hall by an electrical aerosol spectrometer. The highest number concentrations were between 8000 and 12 000 cm(-3), indicating that the use of magnesia alba is no strong source for ultrafine particles. Scanning electron microscopy and energy-dispersive X-ray microanalysis revealed that virtually all particles are hydrated magnesium carbonate hydroxide. In-situ experiments in an environmental scanning electron microscope showed that the particles do not dissolve at relative humidities up to 100%. Thus, it is concluded that solid particles of magnesia alba are airborne and have the potential to deposit in the human respiratory tract. The particle mass concentrations in indoor climbing halls are much higher than those reported for schools and reach, in many cases, levels which are observed for industrial occupations. The observed dust concentrations are below the current occupational exposure limits in Germany of 3 and 10 mg m(-3) for respirable and inhalable dust. However, the dust concentrations exceed the German guide lines for work places without use of hazardous substances. In addition, minimizing dust concentrations to technologically feasible values is required by the current German legislation. Therefore, substantial reduction of the dust concentration is required.

Download full-text PDF

Source
http://dx.doi.org/10.1039/b719344kDOI Listing

Publication Analysis

Top Keywords

indoor climbing
24
microg m-3
24
climbing halls
20
magnesia alba
16
dust concentrations
16
mass concentrations
12
hydrated magnesium
8
magnesium carbonate
8
carbonate hydroxide
8
strong source
8

Similar Publications

Article Synopsis
  • - The study aimed to examine how often upper extremity injuries occur among indoor bouldering climbers and identify risk factors, particularly focusing on dynamic movements used in climbing.
  • - Researchers surveyed 35 climbers, primarily young males, using an online questionnaire and in-person evaluations to analyze injury patterns and their associations with climbing techniques.
  • - Findings indicated a notable link between dynamic climbing styles and shoulder injuries, emphasizing the importance of injury prevention in bouldering, and suggesting different underlying causes compared to other overhead sports.
View Article and Find Full Text PDF

Rock climbing has propelled from niche sport to mainstream free-time activity and Olympic sport. Moreover, climbing can be studied as an example of a high-stakes perception-action task. However, understanding what constitutes an expert climber is not simple or straightforward.

View Article and Find Full Text PDF

Background: Interest in adaptive sports for children with cerebral palsy (CP) is growing, but current evidence on the benefits and indications for one sport, adaptive climbing, is limited.

Purpose: We sought to describe perceived changes observed by parents of children with CP who participated in adaptive climbing.

Methods: Parents whose children with CP participated in 5 or more adaptive climbing sessions were eligible to participate and were emailed a recruitment letter and flyer.

View Article and Find Full Text PDF
Article Synopsis
  • Climbing has shifted from a niche outdoor activity to a popular indoor sport, yet chronic injuries remain prevalent and may be prevented with proper training.
  • A survey conducted among over 1,500 climbers revealed that more than half experienced injuries in the past year, with significant gender differences in injury types and locations.
  • Key findings showed that women commonly injure their shoulders, while men often hurt their fingers, indicating that training focus and climbing style may influence injury risks for different genders.
View Article and Find Full Text PDF

Despite the growing interest in indoor greenery and its positive effects on occupants' well-being, there is limited knowledge on the optimal light levels for indoor plants that ensure energy efficiency and sustainable growth. This study explored the survival of ornamental plants under low-light conditions typical of indoor workplaces without daylight and investigated the impact of increased light intensity or extended day length on their growth. Three species of foliage plants (Epipremnum aureum, Pachira aquatica, and Rhaphidophora tetrasperma) were cultivated in growth chambers with three different lighting schemes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!