A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Electroencephalography burst suppression in a patient with dengue encephalopathy: A case report. | LitMetric

Electroencephalography burst suppression in a patient with dengue encephalopathy: A case report.

Clin Neurophysiol

Department of Neurology, Kaohsiung Municipal Hsiaokang Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan, ROC.

Published: October 2008

Objective: To report a rare case of dengue fever presenting with reversible encephalopathy and burst suppression in the EEG.

Methods: We describe an 85-year-old man with dengue encephalopathy and EEG burst suppression and review the related literature.

Results: The patient presented with an acute comatose state and absent brainstem reflexes. Blood pressure, pulse rate, temperature and oxygen saturation were 94/49mmHg, 82beats/min, 34.7 degrees C, and 83% respectively. Thrombocytopenia and skin rash were found initially. Oxygen saturation was 100% immediately after endotracheal intubation and mechanical ventilation. On the second day he remained comatose with EEG burst suppression but blood pressure and temperature were within normal limits. He regained consciousness and was alert on the 12th day and there was normalization of EEG and thrombocytopenia.

Conclusions: Patients with dengue fever may present as encephalopathy with EEG burst suppression.

Significance: EEG burst suppression does not necessarily suggest a poor prognosis in patients with dengue fever.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.clinph.2008.03.001DOI Listing

Publication Analysis

Top Keywords

burst suppression
20
eeg burst
16
dengue fever
12
dengue encephalopathy
8
encephalopathy eeg
8
blood pressure
8
oxygen saturation
8