Background: We describe our experience with argatroban as a primary or secondary postoperative anticoagulant to heparin in patients receiving ventricular assist devices.

Methods: This is a retrospective review of all Abiomed (BVS5000, AB5000) and Thoratec (PVAD and IVAD) ventricular assist devices from May 2003 through May 2006 at a single institution. Postoperatively, patients received either heparin or argatroban as their anticoagulant. Patients in whom heparin-induced thrombocytopenia was suspected or confirmed were converted from heparin to argatroban.

Results: There were 33 Abiomed and Thoratec ventricular assist devices implanted. Thirteen patients received heparin as their primary postoperative anticoagulant; 8 of the 13 were converted to argatroban as a secondary anticoagulant (hep-arg), and 5 patients remained with heparin as their only anticoagulant. Twenty patients received argatroban as their primary and only postoperative anticoagulant. Thrombocytopenia occurred in 26 patients (79%) overall, 16 (80%) with argatroban only, 6 (75%) with hep-arg, and 4 (80%) with heparin only. Thromboembolic events occurred in 5 patients (15%) overall, 3 (15%) with argatroban only, 1 (13%) with hep-arg, and 1 (20%) with heparin only. Postoperative bleeding requiring reexploration occurred in 5 patients overall (15%), 1 with argatroban only (5%), 3 (38%) with hep-arg, and 1 (20%) with heparin only. Enzyme-linked immunosorbent assay heparin-induced thrombocytopenia tests were positive in 7 patients overall (21%), 5 (25%) with argatroban only, 2 (25%) with hep-arg, and 0 (0%) with heparin only.

Conclusions: Argatroban is a comparable primary or secondary anticoagulant to heparin postoperatively in patients receiving ventricular assist devices.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.athoracsur.2008.01.100DOI Listing

Publication Analysis

Top Keywords

ventricular assist
20
postoperative anticoagulant
16
assist devices
16
argatroban primary
12
primary secondary
12
patients
12
patients received
12
occurred patients
12
argatroban
10
heparin
10

Similar Publications

Left ventricular assist devices (LVADs) have been used as a bridge to transplantation in patients with advanced heart failure. In this case, LVAD therapy was used as a destination therapy for 16 years, representing the longest documented and continuously ongoing support with the original implanted device.

View Article and Find Full Text PDF

Background: Diagnosis of cardiac amyloidosis (CA) is often missed or delayed due to confusion with other causes of increased left ventricular wall thickness. Conventional transthoracic echocardiographic measurements like global longitudinal strain (GLS) has shown promise in distinguishing CA, but with limited specificity. We conducted a study to investigate the performance of a computer vision detection algorithm in across multiple international sites.

View Article and Find Full Text PDF

Objective: Right ventricular failure is a leading cause of mortality among patients with various etiologies of cardiogenic shock. This case series outlines an innovative approach to directly unloading the right ventricle with the Impella LD or 5.5 without crossing the tricuspid valve in cases requiring tricuspid valve repair or replacement.

View Article and Find Full Text PDF

Background: Acute kidney injury (AKI) in the context of acute decompensated heart failure (ADHF) encompasses a broad spectrum of phenotypes with associated disparate outcomes. We evaluate the impact of 'ongoing AKI' on prognosis and cardiorenal outcomes and describe predictors of 'ongoing AKI'.

Methods: A prospective multicentre observational study of patients admitted with ADHF requiring intravenous furosemide was completed, with urinary angiotensinogen (uAGT) measured at baseline.

View Article and Find Full Text PDF

This study aimed to develop and validate a cost-effective, customizable patient-specific phantom for simulating external ventricular drain placement, combining image segmentation, 3-D printing and molding techniques. Two variations of the phantom were created based on patient MRI data, integrating a realistic skin layer with anatomical landmarks, a 3-D printed skull, an agarose polysaccharide gel brain, and a ventricular cavity. To validate the phantom, 15 neurosurgeons, residents, and physician assistants performed 30 EVD placements.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!