Analyzer-based imaging of spinal fusion in an animal model.

Phys Med Biol

Division of Neurosurgery, Royal University Hospital, University of Saskatchewan, Saskatoon, SK, Canada.

Published: May 2008

Analyzer-based imaging (ABI) utilizes synchrotron radiation sources to create collimated monochromatic x-rays. In addition to x-ray absorption, this technique uses refraction and scatter rejection to create images. ABI provides dramatically improved contrast over standard imaging techniques. Twenty-one adult male Wistar rats were divided into four experimental groups to undergo the following interventions: (1) non-injured control, (2) decortication alone, (3) decortication with iliac crest bone grafting and (4) decortication with iliac crest bone grafting and interspinous wiring. Surgical procedures were performed at the L5-6 level. Animals were killed at 2, 4 and 6 weeks after the intervention and the spine muscle blocks were excised. Specimens were assessed for the presence of fusion by (1) manual testing, (2) conventional absorption radiography and (3) ABI. ABI showed no evidence of bone fusion in groups 1 and 2 and showed solid or possibly solid fusion in subjects from groups 3 and 4 at 6 weeks. Metal artifacts were not present in any of the ABI images. Conventional absorption radiographs did not provide diagnostic quality imaging of either the graft material or fusion masses in any of the specimens in any of the groups. Synchrotron-based ABI represents a novel imaging technique which can be used to assess spinal fusion in a small animal model. ABI produces superior image quality when compared to conventional radiographs.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0031-9155/53/10/011DOI Listing

Publication Analysis

Top Keywords

analyzer-based imaging
8
spinal fusion
8
animal model
8
decortication iliac
8
iliac crest
8
crest bone
8
bone grafting
8
conventional absorption
8
abi
7
fusion
6

Similar Publications

Superimposed Wavefront Imaging of Diffraction-enhanced X-rays: sparsity-aware CT reconstruction from limited-view projections.

Int J Comput Assist Radiol Surg

December 2024

High Energy Accelerator Research Organization, Tsukuba, Ibaraki, 305-0801, Japan.

Purpose: In this paper, we describe an algebraic reconstruction algorithm with a total variation regularization (ART + TV) based on the Superimposed Wavefront Imaging of Diffraction-enhanced X-rays (SWIDeX) method to effectively reduce the number of projections required for differential phase-contrast CT reconstruction.

Methods: SWIDeX is a technique that uses a Laue-case Si analyzer with closely spaced scintillator to generate second derivative phase-contrast images with high contrast of a subject. When the projections obtained by this technique are reconstructed, a Laplacian phase-contrast tomographic image with higher sparsity than the original physical distribution of the subject can be obtained.

View Article and Find Full Text PDF

Purpose: Currently, chemoimmunotherapy is effective only in a subset of patients with advanced non-squamous non-small cell lung cancer. Robust biomarkers for predicting the efficacy of chemoimmunotherapy would be useful to identify patients who would benefit from chemoimmunotherapy. The primary objective of our study was to develop an artificial intelligence-based immunoscore and to evaluate the value of patho-immunoscore in predicting clinical outcomes in patients with advanced non-squamous non-small cell lung cancer (NSCLC).

View Article and Find Full Text PDF
Article Synopsis
  • Red blood cell (RBC) indices are essential for diagnosing blood diseases but traditional testing methods require large blood samples and provide average results without detailed cell information.
  • Recent advances in imaging techniques, like spectroscopic differential phase-contrast (sDPC) microscopy, offer a more precise way to measure these indices at the single-cell level with reduced noise.
  • The sDPC method has demonstrated high accuracy in measuring various RBC metrics (like hemoglobin concentration) with less than 7% error compared to standard flow cytometry, and has proven effective in distinguishing between healthy and anemic groups.
View Article and Find Full Text PDF
Article Synopsis
  • Phase-contrast computed tomography (CT) using synchrotron-generated x-rays allows for high-contrast, 3D imaging of soft tissues, but traditional methods suffer from spatial resolution issues due to the required distance between the specimen and the x-ray camera.
  • The new technique, Superimposed Wavefront Imaging of Diffraction-enhanced x-rays (SWIDeX), uses a unique setup to eliminate this distance, resulting in superior spatial resolution compared to conventional methods.
  • The effectiveness of SWIDeX was demonstrated by visualizing internal structures of various human tissues, which showed clearer 3D images when compared to traditional pathological techniques.
View Article and Find Full Text PDF

On the equivalence of the X-ray scattering retrieval with beam tracking and analyser-based imaging using a synchrotron source.

J Phys D Appl Phys

November 2023

Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, WC1E 6BT London, United Kingdom.

X-ray phase contrast imaging (XPCI) methods give access to contrast mechanisms that are based on the refractive properties of matter on top of the absorption coefficient in conventional x-ray imaging. Ultra small angle x-ray scattering (USAXS) is a phase contrast mechanism that arises due to multiple refraction events caused by physical features of a scale below the physical resolution of the used imaging system. USAXS contrast can therefore give insight into subresolution structural information, which is an ongoing research topic in the vast field of different XPCI techniques.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!