Objective: The purpose of this study was to develop a model that accurately represents the interface between bone and basal implants throughout the healing process.

Study Design: The model was applied to the biological scenario of changing load distribution in a basal implant system over time. We did this through finite element analysis (FEA, or finite element method [FEM]), using multiple models with changing bone-implant contact definitions, which reflected the dynamic nature of the interface throughout the bony healing process.

Results: In the simple models, peak von Mises stresses decreased as the bone-implant-contact definition was changed from extremely soft contact (i.e., immature bone during early loading) to hard contact (i.e., mature bone). In upgraded models, which more closely approximate the biological scenario with basal dental implant, peak von Mises stresses decreased at the implant interface; however, they increased at the bone interface as a harder contact definition was modeled. Further, we found a shift in peak stress location within the implants during different contact definitions (i.e., different stages of bony healing). In the case of hard contact, the peak stress occurs above the contact surface, whereas in soft contact, the stress peak occurs in the upper part of the contact area between bone and the vertical shaft of the implant. Only in the extreme soft contact definitions were the peak stresses found near the base plate of the implant.

Conclusion: Future FEM studies evaluating the functional role of dental implants should consider a similar model that takes into account bone tissue adaptations over time.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.tripleo.2007.12.005DOI Listing

Publication Analysis

Top Keywords

finite element
12
contact definitions
12
soft contact
12
contact
11
element analysis
8
bone-implant contact
8
basal implants
8
biological scenario
8
bony healing
8
peak von
8

Similar Publications

Quantum technology exploits fragile quantum electronic phenomena whose energy scales demand ultra-low electron temperature operation. The lack of electron-phonon coupling at cryogenic temperatures makes cooling the electrons down to a few tens of millikelvin a non-trivial task, requiring extensive efforts on thermalization and filtering high-frequency noise. Existing techniques employ bulky and heavy cryogenic metal-powder filters, which prove ineffective at sub-GHz frequency regimes and unsuitable for high-density quantum circuits such as spin qubits.

View Article and Find Full Text PDF

This study analyzes the influences of surface reactions on the natural convective flow, temperature, and oxygen concentration distributions in vertically placed multilayered cavities. A mathematical model for this problem is formulated with proper boundary conditions. At first, the governing equations are made dimensionless using the variable transformations.

View Article and Find Full Text PDF

In order to systematically study the bending behavior of the connection joints of the disc-buckle type formwork support, the accurate numerical model of the disc-buckle type connection joints was obtained through the experimental on the bending behavior of the connection joints of the disc-buckle type, and the bending moment-rotation curve of the joints was verified. The analysis of the failure mode and stress distribution of the joints reveals the importance of the bending behavior of each component. By establishing an accurate numerical model of the joint, the accuracy of the bending experiment of the joint was verified, and the parametric analysis of the influence factors such as the depth of the wedge insertion the disk-plate, the initial position of the wedge insertion the disk-plate, the thickness of the wedge, material constitutive of the wedge and the thickness of the disk-plate was carried out to grasp the influence of the relevant parameters on the bending behavior of the joint.

View Article and Find Full Text PDF

Objective: Electrical Impedance Tomography (EIT) is a non-invasive technique used for lung imaging. A significant challenge in EIT is reconstructing images of deeper thoracic regions due to the low sensitivity of boundary voltages to internal conductivity variations. The current injection pattern is decisive as it influences the current path, boundary voltages, and their sensitivity to tissue changes.

View Article and Find Full Text PDF

Respiratory diseases represent a significant healthcare burden, as evidenced by the devastating impact of COVID-19. Biophysical models offer the possibility to anticipate system behavior and provide insights into physiological functions, advancements which are comparatively and notably nascent when it comes to pulmonary mechanics research. In this context, an Inverse Finite Element Analysis (IFEA) pipeline is developed to construct the first continuously ventilated three-dimensional structurally representative pulmonary model informed by both organ- and tissue-level breathing experiments from a cadaveric human lung.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!