Recent investigation using the Sysmex XE-2100 hematology analyzer (Sysmex Corporation, Japan) has demonstrated erroneously high eosinophil counts and abnormal white blood cell (WBC) scattergrams in malaria cases. This study was conducted to assess the diagnostic efficiency of the Sysmex XE-2100 analyzer for malaria. One hundred forty-four patients initially diagnosed with Plasmodium vivax infection, 319 patients with febrile illness, and 24 patients who underwent malaria treatment were analyzed. Atypical features on Sysmex XE-2100 analyzer were categorized as pseudoeosinophilia (a gap of more than 5% in eosinophil counts between the Sysmex XE-2100 analyzer and microscopic examination) and abnormal WBC scattergram. Pseudoeosinophilia or abnormal WBC scattergram were detected in 100 of 144 malaria-positive samples (sensitivity 69.4%, specificity 100%). The samples with pseudoeosinophilia or abnormal WBC scattergrams showed significantly higher parasite counts than the samples without pseudoeosinophilia or an abnormal WBC scattergram (P<0.05). All 24 samples from patients for whom the malaria smear was repeated after malaria treatment was initiated showed a normalized eosinophil count and a normal WBC histogram. In conclusion, attention to differential count and WBC scattergrams provided by the Sysmex XE-2100 would be a valuable tool in malaria detection.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00277-008-0486-8 | DOI Listing |
Clin Appl Thromb Hemost
February 2024
Jesselson Integrated Heart Center, Shaare Zedek Medical Center and Faculty of Medicine, Hebrew University of Jerusalem, Jerusalem, Israel.
Introduction: Immature platelets or reticulated platelets are newly released thrombocytes. They can be identified by their large size and high RNA cytoplasm concentration. Immature platelet fraction (IPF) represents the percentage of immature circulative platelets relative to the total number of platelets.
View Article and Find Full Text PDFMedicine (Baltimore)
November 2023
Department of Medical Laboratory Science, Kampala International University, Uganda.
Background: Appropriate usage of highly active antiretroviral therapy (HAART) suppresses human immunodeficiency virus (HIV) replication. One of such HAART is dolutegravir (DTG) containing regimen which Nigeria included in her national protocol, as the preferred first-line option, with particularly fixed dose combination of tenofovir/lamivudine/dolutegravir (TLD) in 2018.
Aim: To access the impact of this regimen as against other regimens on some hematological parameters as well as cluster of differentiation 4 (CD4) count and viral load on people living with HIV infection.
Diagnostics (Basel)
May 2023
Department of Research and Development, Hilab, Jose Altair Possebom, 800, Curitiba 81270-185, PR, Brazil.
The complete blood count (CBC) is a highly requested test that is generally restricted to centralized laboratories, which are limited by high cost, being maintenance-demanding, and requiring costly equipment. The Hilab System (HS) is a small, handheld hematological platform that uses microscopy and chromatography techniques, combined with machine learning (ML) and artificial intelligence (AI), to perform a CBC test. This platform uses ML and AI techniques to add higher accuracy and reliability to the results besides allowing for faster reporting.
View Article and Find Full Text PDFSci Rep
February 2023
Division of Hematology and Oncology, Department of Pediatrics I, Medical University of Innsbruck, Innsbruck, Austria.
Febrile neutropenia secondary to chemotherapy is one of the most critical complications in cancer treatment. The aim of this study was to determine if an increase in the percentage of immature platelet fraction (IPF%) might predict early neutrophil recovery following cytostatic-dependent aplasia. A retrospective cohort study compared serial complete blood counts and the level of C-reactive protein (CRP) following induction chemotherapy for Ewing sarcoma and Non-Ewing sarcoma patients.
View Article and Find Full Text PDFLab Med
May 2023
Department of Laboratory Medicine, West China Second University Hospital, Sichuan University, Chengdu, People's Republic of China, Key Laboratory of Birth Defects and Related Diseases of Women and Children (Sichuan University), Ministry of Education, Chengdu, People's Republic of China.
Objective: We aimed to establish appropriate review criteria for blood cell analysis in a specialized women's and children's hospital. Also, the CellaVision DI-60, was developed as one of the automated digital cell morphology analyzer, we evaluated if it was shown to be most effective under the certain review criteria.
Methods: A total of 2890 blood samples were detected to optimize the previously established review criteria for women and children with the Sysmex XE-2100.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!