A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Risk factors for in-stent restenosis after vertebral ostium stenting. | LitMetric

Purpose: To determine whether vascular risk factors, underlying vessel diameter, and/or the type of stent affect restenosis rates for vertebral ostium stents.

Methods: A single-center retrospective analysis was conducted of 44 patients (31 men; mean age 61 years, range 32-81) who underwent stenting of 48 ostial lesions in the vertebral arteries between 1999 and 2005. Only patients who underwent angiographic follow-up were included in the analysis. Cox regression analysis was utilized for risk factor association with binary restenosis (> or =50% versus <50%). Stent types and stent categories were compared for differences in binary restenosis rates and lumen gain at follow-up angiography.

Results: Twenty-three (48%) of 48 lesions had > or =50% stenosis at a mean follow-up of 7.7 months. Cigarette smoking was associated with higher binary restenosis rates (p=0.025), while hypertension, diabetes, hyperlipidemia, history of neck radiation, and known coronary artery and/or peripheral vascular disease were not. Reduced binary restenosis rates and improved lumen gain were seen in cobalt chromium balloon-expandable stents compared to non-cobalt chromium stents (p=0.002 and p=0.002, respectively), stainless steel balloon-expandable stents (p=0.005 and p=0.005), and the S670 stent (p=0.069 and p=0.069). The size of stent used was not associated with risk of restenosis (p=0.756).

Conclusions: Cobalt chromium stents were associated with reduced restenosis, while smoking was associated with increased restenosis risk.

Download full-text PDF

Source
http://dx.doi.org/10.1583/07-2175.1DOI Listing

Publication Analysis

Top Keywords

restenosis rates
12
binary restenosis
12
risk factors
8
restenosis
8
vertebral ostium
8
smoking associated
8
cobalt chromium
8
balloon-expandable stents
8
chromium stents
8
risk
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!