Objective: To develop a headspace gas chromatography method for determining dimethyl sulphate residual in granisetron hydrochloride.
Methods: An Angilent INNOWAX capillary column with nitrogen gas as carrier and FID as detector was applied in this study. Dimethyl sulphate was tested under a constant column temperature.
Result: Dimethyl sulphate had different retention time from other organic solvents such as alcohol,acetoacetate, isopropanol, dichlormethane and chloroform, which might exist in granisetron hydrochloride. The detection limit of dimethyl sulphate;s was 0.0016%.
Conclusion: The method can be used for the determination of dimethyl sulphate residual in granisetron hydrochloride.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3785/j.issn.1008-9292.2008.02.009 | DOI Listing |