The aim of the paper was to compare primary biomechanical stability of different arthrodesis screws (7.3 mm AO screw with and without washer, 6.5 mm Herbert screw and 6.5 mm Ideal Compression Screw (I.CO.S)). The work necessary to achieve an adequate compressive force with them was compared to the measurement with the AO screw with washer, because this method is for the time being the most commonly used one and is called the golden standard. Compressive force was measured indirectly, via screw tension measurement, with strain gauges method. From the measurements we calculated the work to reach a limit of 60 N and the ratios corresponding to the value of the golden standard: I.CO.S (35.2%), Herbert (89.0%), AO-screw without washer (116%). The I.CO.S showed superior results. Only in the case of extremely poor bone quality, a clear advantage of I.CO.S could be expected in practice.
Download full-text PDF |
Source |
---|
J Orthop Case Rep
January 2025
Department of Orthopaedics, SN Medical College, Agra, Uttar Pradesh, India.
Introduction: Posterior cruciate ligament (PCL) avulsion fractures of the tibia with ipsilateral tibial shaft represent a rare but challenging orthopedic injury, necessitating careful consideration of surgical interventions for optimal outcomes. This case report presents the successful management of tibial shaft fracture (proximal 1/3rd junction) along with ipsilateral PCL avulsion fracture of tibia using a novel approach using open reduction internal fixation (ORIF) of tibial shaft with Locking compression plate (LCP) with cannulated cancellous screw and spiked washer fixation of PCL avulsion. There are no case reports or research articles available for the management of PCL avulsion fracture of tibia associated with ipsilateral tibial shaft fracture.
View Article and Find Full Text PDFAm J Sports Med
January 2025
Mayo Clinic Arizona Department of Orthopedic Surgery, Phoenix, Arizona, USA.
Background: The Latarjet and other bony augmentation procedures are commonly used to treat anterior shoulder instability in the setting of significant glenoid bone loss. Although several fixation strategies have been reported, the biomechanical strength of these techniques remains poorly understood.
Purpose: To perform a systematic review of the biomechanical strength of glenoid bony augmentation procedures for anterior shoulder instability.
Eur J Trauma Emerg Surg
December 2024
Department of Trauma and Reconstructive Surgery, BG Klinikum Bergmannstrost Halle gGmbH, Merseburger Strasse 165, 06120, Halle (Saale), Germany.
Purpose: The aim of this study were the retrospective evaluation of the compressive effect and complication rates of transsacral stabilization of osteoporosis-associated sacral fragility fractures in 106 patients using three different implants (6.0 mm sacral bar, n = 32; 7.3 mm screw, n = 26; 7.
View Article and Find Full Text PDFProc Inst Mech Eng H
October 2024
Department of Mechanical and Energy Engineering, Indiana University-Purdue University Indianapolis, IN, USA.
Posterolateral corner and arcuate fractures can cause significant disruption to the stability and kinematics of the knee. This study aimed to determine the biomechanical performance of a novel spiked washer (SW) and intramedullary screw technique compared with a tension slide technique (TST) for the repair of arcuate fractures. Sixteen matched fresh-frozen cadaver knees underwent repair.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!