Iodinated contrast media and the kidney.

Rev Cardiovasc Med

Renal Section and Center for Health Equity Research and Promotion, VA Pittsburgh Healthcare System, Pittsburgh, PA, USA.

Published: July 2008

One of the principal complications of radiographic procedures utilizing intravascular iodinated contrast media is acute kidney injury. Although several clinical and procedural factors impact a patient's risk for contrast-induced acute kidney injury (CIAKI), substantial attention has been focused on the relationship between the type of contrast agent used and renal injury. Multiple contrast agents are available for clinical use, each defined by a series of physicochemical properties. The evolution from high osmolal to low osmolal and, more recently, iso-osmolal contrast media has led to several clinical trials and meta-analyses comparing the nephrotoxicity of different contrast agents. This article summarizes the physicochemical properties that define and differentiate iodinated contrast media, discusses the purported relationship between these properties and kidney injury, and describes the salient findings of clinical trials and meta-analyses that have compared the nephrotoxic effects of contrast agents. Although ongoing and future studies will further elucidate our understanding of the relationship between iodinated contrast and risk for CIAKI, a sound understanding of the currently available data will help inform evidence-based decisions on the use of these agents in clinical practice.

Download full-text PDF

Source

Publication Analysis

Top Keywords

iodinated contrast
16
contrast media
16
kidney injury
12
contrast agents
12
contrast
8
acute kidney
8
agents clinical
8
physicochemical properties
8
clinical trials
8
trials meta-analyses
8

Similar Publications

The vasa vasorum (VV) have gathered considerable interest over the last decade due to its role in vascular wall biology and pathology; however, while the coronary VV are relatively well studied, the anatomy of peripheral VV, such as those of the aorta, remains poorly described, hampering knowledge of their role in peripheral vascular diseases. Through careful retrieval of the porcine thoracic aorta and successful microthrombi removal, the thoracic aorta was perfused with BriteVu™ followed by micro-computed tomography (micro-CT) scanning to image the VV and obtain a 3D reconstruction. We used commercially available software and its thresholding algorithms.

View Article and Find Full Text PDF

Purpose: We aim to develop accurate volumetric quantitative imaging of iodinated contrast agent (ICA) in contrast-enhanced digital breast tomosynthesis (DBT).

Approach: The two main components of the approach are the use of a dual-energy DBT (DE-DBT) scan and the development of an optimization-based algorithm that can yield accurate images with isotropic resolution. The image reconstruction algorithm exploits sparsity in the subject's directional derivative magnitudes, and it also performs direct sparsity regularization to help confine the reconstruction to the true support of the subject.

View Article and Find Full Text PDF

Background: We retrospectively examined image quality (IQ) of thin-slice virtual monochromatic imaging (VMI) of half-iodine-load, abdominopelvic, contrast-enhanced CT (CECT) by dual-energy CT (DECT) with deep learning image reconstruction (DLIR).

Methods: In 28 oncology patients with moderate-to-severe renal impairment undergoing half-iodine-load (300 mgI/kg) CECT by DECT during the nephrographic phase, we reconstructed VMI at 40-70 keV with a slice thickness of 0.625 mm using filtered back-projection (FBP), hybrid iterative reconstruction (HIR), and DLIR; measured contrast-noise ratio (CNR) of the liver, spleen, aorta, portal vein, and prostate/uterus; and determined the optimal keV to achieve the maximal CNR.

View Article and Find Full Text PDF

Objectives: To explore the feasibility of a one-beat protocol and ultra-low tube voltage of 60 kVp in coronary CT angiography (CCTA).

Methods: This prospective study enrolled 107 patients (body mass index ≤ 26 kg/m) undergoing CCTA examinations. Specifically, the conventional group (n = 52) underwent 100 kVp scanning with 45 ml iodine contrast agent and 4 ml/s injection rate, and the low-dose group (n = 55) underwent 60 kVp scanning with 28 ml iodine contrast agent and 2.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!