We examined the reliability of multifocal visual evoked potentials for evaluating visual-field defects in a child with epilepsy and an arachnoid cyst. Multifocal visual evoked potentials were measured both when perimetry was difficult and several years later, when kinetic perimetry became possible in a child with epilepsy and homonymous hemianopia, as suggested by computed tomography of the brain. The peak latency and amplitude of response waves were used for assessment. The recordings of multifocal visual evoked potentials at both times revealed marked decreases in amplitude in the left visual hemifield. This area of decreased amplitude corresponded to the location of the lesion observed with imaging techniques, and was consistent with the left homonymous hemianopia observed via kinetic perimetry. The objective evaluation of visual-field defects through multifocal visual evoked potentials may be useful in children in whom conventional perimetry is difficult.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.pediatrneurol.2008.01.002DOI Listing

Publication Analysis

Top Keywords

multifocal visual
16
visual evoked
16
evoked potentials
16
visual-field defects
8
child epilepsy
8
perimetry difficult
8
kinetic perimetry
8
homonymous hemianopia
8
multifocal
5
perimetry
5

Similar Publications

Purpose: The purpose of this study was to develop ground-truth histology about contributors to variable fundus autofluorescence (FAF) signal and thus inform patient selection for treating geographic atrophy (GA) in age-related macular degeneration (AMD).

Methods: One woman with bilateral multifocal GA, foveal sparing, and thick choroids underwent 535 to 580 nm excitation FAF in 6 clinic visits (11 to 6 years before death). The left eye was preserved 5 hours after death.

View Article and Find Full Text PDF

Objective: Toric intraocular lens implantation has been used to correct corneal astigmatism during cataract surgery. The study aimed to compare the visual outcomes between manual vs markerless toric intraocular lens implantation in astigmatic correction.

Methods: The medical records of patients at American Eye Center who underwent phacoemulsification by multiple surgeons with insertion of monofocal or multifocal toric lenses via manual marking and markerless method from 2010-2019 were reviewed.

View Article and Find Full Text PDF

Investigation into Drug-Induced Liver Damage Using Multimodal Mass Spectrometry Imaging.

J Am Soc Mass Spectrom

January 2025

Maastricht MultiModal Molecular Imaging Institute (M4i), Division of Imaging Mass Spectrometry, Maastricht University, Universiteitssingel 50, 6229 ER Maastricht, The Netherlands.

Drug toxicity during the development of candidate pharmaceuticals is the leading cause of discontinuation in preclinical drug discovery and development. Traditionally, the cause of the toxicity is often determined by histological examination, clinical pathology, and the detection of drugs and/or metabolites by liquid chromatography-mass spectrometry (LC-MS). While these techniques individually provide information on the pathological effects of the drug and the detection of metabolites, they cannot provide specific molecular spatial information without additional experiments.

View Article and Find Full Text PDF

An intraocular lens (IOL) replaces the natural crystalline lens during cataract surgery, and although the vast majority of implants have simple optics, "advanced technology" IOLs have multifocal and extended depth of focus (EDOF) properties. Optical concepts are evaluated here, with image contrast, focal range, and unwanted visual phenomena being the primary concerns. Visual phenomena with earlier bifocal diffractive lenses led to alternative diffractive designs (trifocals, etc.

View Article and Find Full Text PDF

Optical resolution photoacoustic imaging of uneven samples without z-scanning is transformative for the fast analysis and diagnosis of diseases. However, current approaches to elongate the depth of field (DOF) typically imply cumbersome postprocessing procedures, bulky optical element ensembles, or substantial excitation beam side lobes. Metasurface technology allows for the phase modulation of light and the miniaturization of imaging systems to wavelength-size thickness.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!