We examined the reliability of multifocal visual evoked potentials for evaluating visual-field defects in a child with epilepsy and an arachnoid cyst. Multifocal visual evoked potentials were measured both when perimetry was difficult and several years later, when kinetic perimetry became possible in a child with epilepsy and homonymous hemianopia, as suggested by computed tomography of the brain. The peak latency and amplitude of response waves were used for assessment. The recordings of multifocal visual evoked potentials at both times revealed marked decreases in amplitude in the left visual hemifield. This area of decreased amplitude corresponded to the location of the lesion observed with imaging techniques, and was consistent with the left homonymous hemianopia observed via kinetic perimetry. The objective evaluation of visual-field defects through multifocal visual evoked potentials may be useful in children in whom conventional perimetry is difficult.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.pediatrneurol.2008.01.002 | DOI Listing |
Invest Ophthalmol Vis Sci
January 2025
Vitreous Retina Macula Consultants of New York, New York, United States.
Purpose: The purpose of this study was to develop ground-truth histology about contributors to variable fundus autofluorescence (FAF) signal and thus inform patient selection for treating geographic atrophy (GA) in age-related macular degeneration (AMD).
Methods: One woman with bilateral multifocal GA, foveal sparing, and thick choroids underwent 535 to 580 nm excitation FAF in 6 clinic visits (11 to 6 years before death). The left eye was preserved 5 hours after death.
Acta Med Philipp
December 2024
Department of Ophthalmology and Visual Sciences, Philippine General Hospital, University of the Philippines Manila, Manila, Philippines.
Objective: Toric intraocular lens implantation has been used to correct corneal astigmatism during cataract surgery. The study aimed to compare the visual outcomes between manual vs markerless toric intraocular lens implantation in astigmatic correction.
Methods: The medical records of patients at American Eye Center who underwent phacoemulsification by multiple surgeons with insertion of monofocal or multifocal toric lenses via manual marking and markerless method from 2010-2019 were reviewed.
J Am Soc Mass Spectrom
January 2025
Maastricht MultiModal Molecular Imaging Institute (M4i), Division of Imaging Mass Spectrometry, Maastricht University, Universiteitssingel 50, 6229 ER Maastricht, The Netherlands.
Drug toxicity during the development of candidate pharmaceuticals is the leading cause of discontinuation in preclinical drug discovery and development. Traditionally, the cause of the toxicity is often determined by histological examination, clinical pathology, and the detection of drugs and/or metabolites by liquid chromatography-mass spectrometry (LC-MS). While these techniques individually provide information on the pathological effects of the drug and the detection of metabolites, they cannot provide specific molecular spatial information without additional experiments.
View Article and Find Full Text PDFBiomed Opt Express
January 2025
Center for Visual Science, The Institute of Optics, Flaum Eye Institute. University of Rochester, Rochester, NY, USA.
An intraocular lens (IOL) replaces the natural crystalline lens during cataract surgery, and although the vast majority of implants have simple optics, "advanced technology" IOLs have multifocal and extended depth of focus (EDOF) properties. Optical concepts are evaluated here, with image contrast, focal range, and unwanted visual phenomena being the primary concerns. Visual phenomena with earlier bifocal diffractive lenses led to alternative diffractive designs (trifocals, etc.
View Article and Find Full Text PDFSci Adv
January 2025
Department of Biophysics, Institute of Quantum Biophysics, Sungkyunkwan University, Suwon 16419, Republic of Korea.
Optical resolution photoacoustic imaging of uneven samples without z-scanning is transformative for the fast analysis and diagnosis of diseases. However, current approaches to elongate the depth of field (DOF) typically imply cumbersome postprocessing procedures, bulky optical element ensembles, or substantial excitation beam side lobes. Metasurface technology allows for the phase modulation of light and the miniaturization of imaging systems to wavelength-size thickness.