The relative configuration of acyclic alpha-alkyl-beta-hydroxy carbonyl compounds can be determined by using (1)H NMR spectroscopy. The assignment can be achieved by recording the (1)H NMR spectrum of the syn-anti mixture. The upfield carbinol hydrogen signal belongs to the anti whereas the downfield to the syn stereoisomer.

Download full-text PDF

Source
http://dx.doi.org/10.1021/jo800066aDOI Listing

Publication Analysis

Top Keywords

relative configuration
8
configuration acyclic
8
acyclic alpha-alkyl-beta-hydroxy
8
alpha-alkyl-beta-hydroxy carbonyl
8
carbonyl compounds
8
convenient method
4
method assignment
4
assignment relative
4
compounds nmr
4
nmr relative
4

Similar Publications

Stereoselective Reaction Enabling Simultaneous Analysis of Carbon-Carbon Double-Bond Configuration and the Position of Monounsaturated Fatty Acids through UHPLC-ESI-MRM-MS.

Anal Chem

January 2025

Beijing National Laboratory for Molecular Sciences, CAS Research/Education Center for Excellence in Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Beijing Mass Spectrum Center, Institute of Chemistry Chinese Academy of Sciences, Beijing 100190, China.

Monounsaturated fatty acids (MUFA) are an important class of nutrients and are involved in lipid metabolism. The positions of the C=C bond and cis-trans isomerism have a significant influence on their physiological activity. However, simultaneously detecting these two structural properties has been challenging due to multiple isomers of MUFA.

View Article and Find Full Text PDF

Event cameras only report changes in brightness when thresholds in individual pixels relative to previous levels are crossed. They output sparse streams of events that quantify these changes spatially and temporally. We have developed a measurement system using two event cameras in a stereo configuration with a specialized projector for 3D measurements of static objects.

View Article and Find Full Text PDF

Utilizing the periodic pixel configuration of the CCD/CMOS imaging sensor as the reference grating and the image of the real grating formed by the lens as the specimen grating, the CCD Moiré method directly outputs amplified Moiré fringes, facilitating high-resolution, full-field deformation measurement. Due to the amplification effect of CCD Moiré, even minor relative rotations of the two gratings can significantly affect Moiré imaging and introduce measurable errors. This paper mainly addresses the imaging and measurement challenges of in-plane rotation in the CCD Moiré method.

View Article and Find Full Text PDF

Adaptive optics (AO) improves the spatial resolution of microscopy by correcting optical aberrations. While its application has been well established in microscopy modalities utilizing a circular pupil, its adaptation to systems with non-circular pupils, such as Bessel-focus two-photon fluorescence microscopy (2PFM) with an annular pupil, remains relatively uncharted. Herein, we present a modal focal AO (MFAO) method for Bessel-focus 2PFM.

View Article and Find Full Text PDF

Background: Health authorities worldwide have invested in digital technologies to establish robust information exchange systems for improving the safety and efficiency of medication management. Nevertheless, inaccurate medication lists and information gaps are common, particularly during care transitions, leading to avoidable harm, inefficiencies, and increased costs. Besides fragmented health care processes, the inconsistent incorporation of patient-driven changes contributes to these problems.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!