Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 144
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 144
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 212
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3106
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
We describe quality assurance paradigms for ultrasound imaging systems for target localization (UISTL). To determine the absolute localization accuracy of a UISTL, an absolute coordinate system can be established in the treatment room and spherical targets at various depths can be localized. To test the ability of such a system to determine the magnitude of internal organ motion, a phantom that mimics the human male pelvic anatomy can be used to simulate different organ motion ranges. To assess the interuser variability of ultrasound (US) guidance, different experienced users can independently determine the daily organ shifts for the same patients for a number of consecutive fractions. The average accuracy for a UISTL for the localization of spherical targets at various depths has been found to be 0.57 +/- 0.47 mm in each spatial dimension for various focal depths. For the phantom organ motion test it was found that the true organ motion could be determined to within 1.0 mm along each axis. The variability between different experienced users who localized the same 5 patients for five consecutive fractions was small in comparison to the indicated shifts. In addition to the quality assurance tests that address the ability of a UISTL to accurately localize a target, a thorough quality assurance program should also incorporate the following two aspects to ensure consistent and accurate localization in daily clinical use: (1) adequate training and performance monitoring of users of the US target localization system, and (2) prescreening of patients who may not be good candidates for US localization.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ijrobp.2007.05.088 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!