A stable isotope breath test with a standard meal for abnormal gastric emptying of solids in the clinic and in research.

Clin Gastroenterol Hepatol

Clinical Enteric Neuroscience Translational and Epidemiological Research, College of Medicine, Mayo Clinic, Rochester, Minnesota 55905, USA.

Published: June 2008

Background & Aims: The aim of this study was to validate a [13C]-Spirulina platensis gastric emptying (GE) breath test (GEBT) with a standardized meal.

Methods: Thirty-eight healthy volunteers and 129 patients with clinically suspected delayed GE underwent measurements at 45, 90, 120, 150, 180, and 240 minutes after a 238 kcal meal labeled test with 100 mg [13C]-S platensis and 0.5 mCi 99mTc. We established normal ranges for scintigraphy with this test meal, intraindividual and interindividual coefficients of variation (COVs), and the ability of the [13C] GEBT breath percent dose excreted *1000 values to predict scintigraphic half-life and to categorize GE as delayed, normal, or accelerated.

Results: In health, the 10th and 90th percentiles of half-life for scintigraphic GE with this meal were 52 and 86 minutes; intraindividual COVs for scintigraphy and the GEBT were, respectively, 31% and 27% at 45 minutes, 17% and 21% at 90 minutes, 13% and 16% at 120 minutes, 10% and 13% at 150 minutes, and 8% and 12% at 180 minutes. Interindividual COVs at each time for the [13C] GEBT and scintigraphy were typically approximately 1%-4% lower than intraindividual COVs. Individual breath samples at 45, 150, and 180 minutes predicted GE category; at 80% specificity, 45- and 180-minute samples combined were 93% sensitive to identify accelerated GE, and 150- and 180-minute combined were 89% sensitive for delayed GE.

Conclusions: [13C]-S platensis GEBT is as reproducible as scintigraphy; imprecision with both tests reflects physiologic variation. With 4 breath samples, this method with an off-the-shelf meal is valid to assess GE in clinic and in research.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3739971PMC
http://dx.doi.org/10.1016/j.cgh.2008.01.009DOI Listing

Publication Analysis

Top Keywords

breath test
8
gastric emptying
8
150 180
8
minutes
8
[13c]-s platensis
8
[13c] gebt
8
intraindividual covs
8
180 minutes
8
breath samples
8
breath
5

Similar Publications

. To develop an augmentation method that simulates cone-beam computed tomography (CBCT) related motion artifacts, which can be used to generate training-data to increase the performance of artificial intelligence models dedicated to auto-contouring tasks.The augmentation technique generates data that simulates artifacts typically present in CBCT imaging.

View Article and Find Full Text PDF

Utility of a C-Spirulina Stable Isotope Gastric Emptying Breath Test in Diabetes Mellitus.

Neurogastroenterol Motil

January 2025

Division of Gastroenterology and Hepatology, Mayo Clinic, Rochester, Minnesota, USA.

Background: The carbon-13 spirulina gastric emptying breath test (GEBT) is approved to identify delayed, but not accelerated, gastric emptying (GE). We compared the utility of the GEBT to scintigraphy for diagnosing abnormal GE in patients with diabetes mellitus.

Methods: Twenty-eight patients with diabetes ate a 230-kcal test meal labeled with technetium 99 m and C-spirulina, after which 10 scintigraphic images and breath samples (baseline, 15, 30, 45, 60, 90, 120, 150, 180, 210, and 240 min) were collected on 2 occasions 1 week apart.

View Article and Find Full Text PDF

Background: Management of respiratory motion during radiation therapy is essential for accurate dose delivery and minimizing the risk to organs. In diagnostic imaging, respiratory monitoring is required for confirmation of breath-hold and four-dimensional computed tomography (CT) reconstruction. Although respiratory monitoring systems are widely used in radiation therapy, they are not often used for diagnostic imaging, where they could improve image quality.

View Article and Find Full Text PDF

Severe bradycardia in patients with obstructive sleep apnoea and good early response to CPAP.

Sleep Breath

January 2025

Department of Cardiac and Vascular Diseases, Jagiellonian University Medical College, John Paul II Hospital, Prądnicka 80, Kraków, 31-202, Poland.

Background: Obstructive sleep apnoea (OSA) may lead to heart rhythm abnormalities including bradycardia. Our aim was to ascertain clinical and echocardiographic parameters in patients with OSA in whom severe bradycardia was detected in an outpatient setting, as well as to evaluate the efficacy of CPAP therapy on heart rate normalization at the early stages of treatment.

Methods: Fifteen patients mild, moderate or severe OSA and concomitant bradycardia were enrolled.

View Article and Find Full Text PDF

Phenotypical Characterization of Gastroenterological and Metabolic Manifestations in Patients With Williams-Beuren Syndrome.

Am J Med Genet A

January 2025

Gastroenterology and Endoscopy Unit, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy.

Gastrointestinal (GI) symptoms are common in patients with Williams-Beuren syndrome (WBS), but their prevalence and possible causes are not yet fully known. This study assessed GI symptoms' prevalence and their possible origin by performing a predefined set of tests in adult WBS patients. Laboratory tests and a questionnaire were administered to assess GI symptoms and dietary habits.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!