X-ray imaging performance of scintillator-filled silicon pore arrays.

Med Phys

Philips Research Europe, Weisshausstr 2, 52080 Aachen, Germany.

Published: March 2008

The need for fine detail visibility in various applications such as dental imaging, mammography, but also neurology and cardiology, is the driver for intensive efforts in the development of new x-ray detectors. The spatial resolution of current scintillator layers is limited by optical diffusion. This limitation can be overcome by a pixelation, which prevents optical photons from crossing the interface between two neighboring pixels. In this work, an array of pores was etched in a silicon wafer with a pixel pitch of 50 microm. A very high aspect ratio was achieved with wall thicknesses of 4-7 microm and pore depths of about 400 microm. Subsequently, the pores were filled with Tl-doped cesium iodide (CsI:Tl) as a scintillator in a special process, which includes powder melting and solidification of the CsI. From the sample geometry and x-ray absorption measurement the pore fill grade was determined to be 75%. The scintillator-filled samples have a circular active area of 16 mm diameter. They are coupled with an optical sensor binned to the same pixel pitch in order to measure the x-ray imaging performance. The x-ray sensitivity, i.e., the light output per absorbed x-ray dose, is found to be only 2.5%-4.5% of a commercial CsI-layer of similar thickness, thus very low. The efficiency of the pores to transport the generated light to the photodiode is estimated to be in the best case 6.5%. The modulation transfer function is 40% at 4 lp/mm and 10%-20% at 8 lp/mm. It is limited most likely by the optical gap between scintillator and sensor and by K-escape quanta. The detective quantum efficiency (DQE) is determined at different beam qualities and dose settings. The maximum DQE(0) is 0.28, while the x-ray absorption with the given thickness and fill factor is 0.57. High Swank noise is suspected to be the reason, mainly caused by optical scatter inside the CsI-filled pores. The results are compared to Monte Carlo simulations of the photon transport inside the pore array structure. In addition, some x-ray images of technical and anatomical phantoms are shown. This work shows that scintillator-filled pore arrays can provide x-ray imaging with high spatial resolution, but are not suitable in their current state for most of the applications in medical imaging, where increasing the x-ray doses cannot be tolerated.

Download full-text PDF

Source
http://dx.doi.org/10.1118/1.2839441DOI Listing

Publication Analysis

Top Keywords

x-ray imaging
12
x-ray
10
imaging performance
8
pore arrays
8
spatial resolution
8
limited optical
8
pixel pitch
8
x-ray absorption
8
pore
5
optical
5

Similar Publications

Orthotopic tumor models in pre-clinical translational research are becoming increasingly popular, raising the demands on accurate tumor localization prior to irradiation. This task remains challenging both in X-ray and proton computed tomography (xCT and pCT, respectively), due to the limited contrast of tumor tissue compared to the surrounding tissue. We investigate the feasibility of gadolinium oxide nanoparticles as multimodal contrast enhancement agent for both imaging modalities.

View Article and Find Full Text PDF

The feasibility of the adult age estimation 3D-CBCT method on ancient human remains.

J Forensic Odontostomatol

December 2024

Laboratory of Personal Identification and Forensic Morphology, Department of Health Sciences, University of Florence, Florence, Italy.

The age estimation of skeletal remains still represents a central issue not only for the reconstruction of the so-called "biological profile," but mostly for the palaeodemographic investigation. This research aims at verifying the feasibility of the adult age estimation method developed on living people by Pinchi et al. (2015 and 2018), for estimating the age at the death of 37 subjects from ancient populations found in two different Italian necropolis of archaeological interest (Mont'e Prama and Florence, X-IX century B.

View Article and Find Full Text PDF

This study aims to compare the accuracy of Demirjian's and Cameriere's methods in determining adult age at the 18-year threshold using mandibular third molars in the Thai population. Panoramic radiograph images of 504 healthy subjects aged between 14 and 23 years were retrospectively collected. The developmental stages of mandibular third molars were evaluated using Demirjian's method, while the maturity index of mandibular third molars (I3M) was assessed using Cameriere's method.

View Article and Find Full Text PDF

Objectives: The study aims to evaluate the pulp-to-tooth area ratio in permanent maxillary central incisors, lateral incisors, and canines for age estimation using three-dimensional cone beam computed tomography images.

Methods: Hundred cone-beam computed tomography (CBCT) images of patients aged between 12-70 years were retrospectively studied using NNT Viewer software version 13. Pulpal and teeth area were evaluated with the "area tool" in the acquired images in all three planes, and the pulp-to-tooth area ratio (PTR) was calculated with the measurements obtained.

View Article and Find Full Text PDF

Third molar maturity index for discriminating between adults and minors: validation in an Iranian sample.

J Forensic Odontostomatol

December 2024

Department of Oral and Maxillofacial Radiology, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran.

The life-altering effects of criminal trials necessitate providing reliable methods to distinguish adults (≥18) from minors (< 18). The present study aims to evaluate the accuracy of the third molar maturity index (I3M) introduced by Cameriere et al. (2008) in distinguishing adults from minors in the Iranian population.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!