J Trauma
Division of Burn, Trauma, Critical Care, Department of Surgery, University of Texas Southwestern Medical Center at Dallas, Dallas, Texas, USA.
Published: April 2008
Background: Cardioprotection with beta-receptor antagonists improves outcome in high risk patients undergoing elective surgery. Recent trials have demonstrated an association between beta blocker (BB) use and improved outcomes after injury. The mechanisms through which BB result in improved outcomes remain poorly elucidated. In vitro evidence supports that BB modulates the postinjury inflammatory response. The purpose of this study was to examine the effects of BB on inflammatory profiles in injured patients at increased risk for heart disease.
Methods: A pseudo-randomized, controlled trial of injured patients over 55 admitted to the intensive care unit was conducted. Patients were randomized to receive continuous BB or standard of care. Patients with a reported history of prehospital BB use were enrolled into an observational arm of the trial, continued on BB, and analyzed with the continuous BB group. Plasma interleukin (IL)-6 and IL-1beta levels were measured by enzyme-linked immunosorbent assay at baseline and day 1, 2, and 4 after BB initiation. Cytokine data were log transformed for normality assumptions. Repeated measures analysis of variance was used to test for within-group differences in cytokine levels over time.
Results: Forty-two patients were enrolled. Seventeen patients were randomized to the control group and 25 patients received continuous BB (10 randomized/15 observational). There was no difference in gender, age, prior history of heart disease, or admission heart rate, systolic blood pressure or initial base deficit between groups. Baseline levels of IL-6 and IL-1beta did not differ between groups. Levels of IL-6, but not IL-1beta, decreased over time in patients receiving BB (p = 0.04), whereas levels in controls remained unchanged (p = 0.27). There were no BB related complications.
Conclusions: Use of BB decreases serum IL-6 levels over time in injured patients at risk for heart disease. This may contribute to improved outcomes noted in trauma patients receiving BB. Additionally, BB use in this population of patients is safe after endpoints of resuscitation have been met.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/TA.0b013e3181684cf0 | DOI Listing |
Drug Alcohol Depend
January 2025
RAND, Boston, MA, United States. Electronic address:
Importance: States have implemented multiple policies likely to influence opioid prescribing; few national general population studies examine those policies' effects on per-capita opioid morphine milligram equivalents (MME) dispensed.
Objective: To examine state policies' effects on opioids per-capita MMEs dispensed at retail pharmacies.
Design: A longitudinal study of associations between MME per capita and implementation of policy interventions at different times across states.
Comput Med Imaging Graph
January 2025
CAS Key Laboratory of Molecular Imaging, Institute of Automation, Chinese Academy of Sciences, Beijing 100190, China; School of Artificial Intelligence, University of Chinese Academy of Sciences, Beijing 100049, China; National Key Laboratory of Kidney Diseases, Beijing 100853, China. Electronic address:
In clinical optical molecular imaging, the need for real-time high frame rates and low excitation doses to ensure patient safety inherently increases susceptibility to detection noise. Faced with the challenge of image degradation caused by severe noise, image denoising is essential for mitigating the trade-off between acquisition cost and image quality. However, prevailing deep learning methods exhibit uncontrollable and suboptimal performance with limited interpretability, primarily due to neglecting underlying physical model and frequency information.
View Article and Find Full Text PDFEur J Radiol
January 2025
Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany; Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, USA. Electronic address:
Purpose: To evaluate the feasibility of aortoiliac CT-Angiography (CTA) using dual-source photon-counting detector (PCD)-CT with minimal iodine dose.
Methods: This IRB-approved, single-center prospective study enrolled patients with indications for aortoiliac CTA from December 2022 to March 2023. All scans were performed using a first-generation dual-source PCD-CT.
Eur J Radiol
January 2025
Department of Radiology and Nuclear Medicine, University Medical Center Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany. Electronic address:
Objectives: Coronary CT angiography (CCTA) is an excellent tool in ruling out coronary artery disease (CAD) but tends to overestimate especially highly calcified plaques. To reduce diagnostic invasive catheter angiographies (ICA), current guidelines recommend CT-FFR to determine the hemodynamic significance of coronary artery stenosis. Photon-Counting Detector CT (PCCT) revolutionized CCTA and may improve CT-FFR analysis in guiding patients.
View Article and Find Full Text PDFEur J Radiol
January 2025
Third Hospital of Shanxi Medical University, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Taiyuan, 030032, China; Department of Pulmonary and Critical Care Medicine, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Third Hospital of Shanxi Medical University, Tongji Shanxi Hospital, Taiyuan, 030032, China; Department of Pulmonary and Critical Care Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China. Electronic address:
Purpose: This head-to-head comparative meta-analysis aimed to evaluate the comparative diagnostic efficacy of [F]FDG PET/CT and dynamic contrast-enhanced CT(DCE-CT) for the differentiation between malignant and benign pulmonary nodules.
Methods: An extensive search was conducted in the PubMed, Embase, and Web of Science to identify available publications up to March 23, 2024. Studies were included if they evaluated the diagnostic efficacy of [F]FDG PET/CT and DCE-CT for the characterization of pulmonary nodules.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!
© LitMetric 2025. All rights reserved.