Background: Intrauterine devices (IUDs) are safe and effective methods of long-term reversible contraception. The design and copper content as well as placement of the copper on IUDs could affect their effectiveness and side effect profile. We compared different copper IUDs for their effectiveness and side effects.

Study Design: We searched multiple electronic databases with appropriate keywords and names of the IUDs known to be on the market. We searched the reference lists of papers identified and contacted authors when possible. There was no language restriction. Randomized controlled trials comparing different IUDs that reported on clinical outcomes were considered for inclusion. Two reviewers independently extracted data on outcomes and trial characteristics. We combined the trial results in meta-analyses and expressed results as rate difference (RD) using a fixed-effects model with 95% confidence interval (CI). In the presence of significant heterogeneity, a random-effects model was applied.

Results: We included 35 trials, resulting in 18 comparisons of 10 different IUDs in approximately 48,000 women. TCu380A was more effective in preventing pregnancy than MLCu375 (RD 1.70%, 95% CI 0.07-2.95% after 4 years of use). TCu380A was also more effective than MLCu250, TCu220 and TCu200. There tended to be fewer pregnancies with TCu380S compared to TCu380A after the first year of use, a difference which was statistically significant in the fourth year (RD -1.62%, 95% CI -3.00% to -0.24%). This occurred despite more expulsions with TCu380S (RD 3.50%, 95% CI 0.36-6.63% at 4 years). MLCu375 was no more effective than TCu220 at 1 year of use, or MLCu250 and NovaT up to 3 years. Compared to TCu380A or TCu380S, none of the IUDs showed any benefits in terms of bleeding or pain or any of the other reasons for early discontinuation. None of the trials that reported events at insertion found one IUD easier to insert than another or caused less pain at insertion. There is no evidence that uterine perforation rates vary by type of device. There are minimal randomized data on IUD use in nulliparous women.

Conclusions: TCu380A and TCu380S appear to be more effective than other IUDs. No IUD showed consistently lower removal rates for bleeding and pain in comparison to other IUDs. There is no evidence that any particular framed copper device is better suited to women who have not had children.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.contraception.2007.12.011DOI Listing

Publication Analysis

Top Keywords

iuds
9
intrauterine devices
8
randomized controlled
8
controlled trials
8
copper iuds
8
effectiveness side
8
tcu380a effective
8
compared tcu380a
8
tcu380a tcu380s
8
bleeding pain
8

Similar Publications

Introduction: The intrauterine device (IUD) inserted immediately after delivery is a safe and effective measure for preventing unplanned pregnancies. Despite exhibiting a higher expulsion rate compared with later insertions, it proves cost-effective due to the high rate of continuity of the method. There is still a gap in the literature regarding the optimal strategy for monitoring these patients, whether it should be through clinical examination, ultrasound or both.

View Article and Find Full Text PDF

Fertility Sparing in Endometrial Cancer: Where Are We Now?

Cancers (Basel)

January 2025

Department of Molecular and Developmental Medicine, Obstetrics and Gynecological Clinic, University of Siena, 53100 Siena, Italy.

Endometrial cancer is the most common gynecological neoplasm with an increased incidence in the premenopausal population in recent decades. This raises the problem of managing endometrial cancer in fertile women who have not yet achieved pregnancy. In these women, after careful selection, hysterectomy may be postponed in favor of conservative management if specific requirements are met.

View Article and Find Full Text PDF

Background: The intrauterine device (IUD) is a highly effective form of long-acting reversible contraception, widely recognized for its convenience and efficacy. Despite its benefits, many patients report moderate to severe pain during and after their IUD insertion procedure. Furthermore, reports suggest significant variability in pain control medications, including no adequate pain medication.

View Article and Find Full Text PDF

Introduction: India is committed to achieving universal health care for all by 2030. The objective of social marketing is to promote public health and its goal is to improve health for all, but there are some challenges like irregular availability, quality issue, inadequacy of marketing causes under- utilization of the government supplied health consumables.

Objectives: Present study aims to find out the usage pattern and assess the perceived satisfaction level of beneficiaries of using various socially marketed health consumables at government settings and explore the perception of healthcare personnel regarding barriers to its usage in a rural area of India.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!