Grafting BSA onto poly[(L-lactide)-co-carbonate] microspheres by click chemistry.

Macromol Biosci

State Key Laboratory of Polymer Physics and Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, China.

Published: July 2008

Model protein bovine serum albumin (BSA) was covalently grafted onto poly[(L-lactide)-co-carbonate] microsphere surfaces by "click chemistry." The grafting was confirmed by confocal laser scanning microscopy and X-ray photoelectron spectroscopy. The maximum amount of surface-grafted BSA was 45 mg x g(-1). The secondary structure of the grafted BSA was analyzed by FTIR and the results demonstrated that the grafting did not affect protein structure. This strategy can also be used on microspheres prepared from poly(L-lactide)/poly[(L-lactide)-co-carbonate] blend materials.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mabi.200700306DOI Listing

Publication Analysis

Top Keywords

grafting bsa
4
bsa poly[l-lactide-co-carbonate]
4
poly[l-lactide-co-carbonate] microspheres
4
microspheres click
4
click chemistry
4
chemistry model
4
model protein
4
protein bovine
4
bovine serum
4
serum albumin
4

Similar Publications

BSA/PEI/GOD modified cellulose nanocrystals for construction of hydrogel-based flexible glucose sensors for sweat detection.

J Mater Chem B

January 2025

School of Chemistry and Materials Science, Ludong University, Key Laboratory of High Performance and Functional Polymer in the Universities of Shandong Province, Collaborative Innovation Center of Shandong Province for High Performance Fibers and Their Composites, Yantai 264025, China.

With the miniaturization, integration and intelligence of sweat electrochemical sensor technology, hydrogel flexible sensors have demonstrated immense potential in the field of real-time and non-invasive personal health monitoring. However, it remains a challenge to integrate excellent mechanical properties, self-healing properties, and electrochemical sensing capabilities into the preparation of hydrogel-based flexible sensors. The utilization of CBPG (cellulose nanocrystals (CNCs)@bovine serum albumin (BSA)@polyethyleneimine (PEI) glucose oxidase (GOD) nanomaterial) as both an enhancing phase and sensor probe within a hydrogel matrix, with poly(vinyl alcohol) (PVA) serving as the primary network constituent, has been proposed as a non-invasive technique for monitoring trace glucose levels in sweat.

View Article and Find Full Text PDF

High-Efficiency Electrochemiluminescence Biosensor with Antifouling and Antibacterial Functions for Sensitive and Accurate Analysis of Chloramphenicol in Seawater.

Anal Chem

January 2025

Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, Ministry of Education; Shandong Key Laboratory of Biochemical Analysis; Key Laboratory of Analytical Chemistry for Life Science in Universities of Shandong; College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao 266042, PR China.

In marine environmental monitoring, due to the presence of a large number of interfering proteins and bacteria in seawater, it is of great significance to construct an efficient sensing interface with antifouling and antibacterial functions to avoid the aforementioned interferences. On this basis, the zwitterionic hydrogel based on sulfobetaine methacrylate (SBMA) and bovine serum albumin (BSA) was developed as an antifouling and antibacterial coating. The combination of hydration of zwitterions and hydrophilicity of hydrogels endows BSA@PSBMA with good antiadsorption ability, which effectively hinders the adhesion of proteins and bacteria, thereby improving the detection sensitivity of the biosensor.

View Article and Find Full Text PDF

Background: The existing criteria for living kidney donors (LKDs)in Japan are controversial. We evaluated the roles of computed tomography volumetry (CTV) and 99 m Tc-diethylenetriamine penta-acetic acid (DTPA) scintigraphy in assessing preoperative and postoperative renal function and predicting early recovery of residual renal function.

Methods: We retrospectively reviewed the medical charts of 175 consecutive LKDs who underwent donor nephrectomy (DN) at our institution between 2006 and 2022.

View Article and Find Full Text PDF

Introduction: When GFR is measured (mGFR) using iohexol plasma clearance, results are reported both as a "non-indexed" (mL/min) and "body-surface area (BSA) indexed" to 1.73 m2. When these two values differ, there is no consensus as to which is preferable to use to determine suitability for living kidney donation (LKD).

View Article and Find Full Text PDF

Severe acute graft-versus-host disease (GVHD) can occur during allogeneic hematopoietic stem cell transplantation (allo-HSCT), causing considerable morbidity and mortality. Although several biomarkers have been reported for predicting acute GVHD, they are often difficult to measure in routine clinical practice. Recently, three-dimensional computed tomography (3D-CT) has been used to quantify the detailed bronchial structure, which might correlate with acute GVHD.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!