Development and application of quantitative methods for monitoring dermal and inhalation exposure to propiconazole.

J Environ Monit

Department of Environmental Sciences and Engineering, School of Public Health, The University of North Carolina at Chapel Hill, CB #7431, Rosenau Hall, Chapel Hill, NC 27599-7431, USA.

Published: March 2008

Quantitative methods to measure dermal and inhalation exposure to the fungicide propiconazole were developed in the laboratory and applied in the occupational exposure setting for monitoring five farm workers' exposure during pesticide preparation and application to peach crops. Dermal exposure was measured with tape-strips applied to the skin, and the amount of propiconazole was normalized to keratin content in the tape-strip. Inhalation exposure was measured with an OVS tube placed in the worker's breathing-zone during pesticide handling. Samples were analyzed by GC-MS in EI+ mode (limit of detection 6 pg microl(-1)). Dermal exposure ranged from non-detectable to 32.1 +/- 22.6 ng per microg keratin while breathing-zone concentrations varied from 0.2 to 2.2 microg m(-3). A positive correlation was observed between breathing-zone concentrations and ambient air temperature (r2 = 0.87, p < 0.01). Breathing-zone concentrations did not correlate with dermal exposure levels (r2 = 0.11, p = 0.52). Propiconazole levels were below limit of detection when rubber gloves, coveralls, and full-face mask were used. The total-body propiconazole dose, determined for each worker by summing the estimated dermal dose and inhalation dose, ranged from 0.01 to 12 microg per kg body weight per day. Our results show that tape-stripping of the skin and the OVS can be effectively utilized to measure dermal and inhalation exposure to propiconazole, respectively, and that the dermal route of exposure contributed substantially more to the total dose than the inhalation route.

Download full-text PDF

Source
http://dx.doi.org/10.1039/b714882hDOI Listing

Publication Analysis

Top Keywords

inhalation exposure
16
dermal inhalation
12
dermal exposure
12
breathing-zone concentrations
12
exposure
10
quantitative methods
8
dermal
8
exposure propiconazole
8
measure dermal
8
exposure measured
8

Similar Publications

Ventilation and features of the lung environment dynamically alter modeled intrapulmonary aerosol exposure from inhaled electronic cigarettes.

Sci Rep

December 2024

Division of Pulmonary and Critical Care, Department of Medicine, David Geffen School of Medicine, University of California, Los Angeles, CA, 90095-1690, USA.

Electronic cigarettes (e-cigs) fundamentally differ from tobacco cigarettes in their generation of liquid-based aerosols. Investigating how e-cig aerosols behave when inhaled into the dynamic environment of the lung is important for understanding vaping-related exposure and toxicity. A ventilated artificial lung model was developed to replicate the ventilatory and environmental features of the human lung and study their impact on the characteristics of inhaled e-cig aerosols from simulated vaping scenarios.

View Article and Find Full Text PDF

Exposure to ambient air pollution is associated with several noncommunicable diseases, and it adversely affects the respiratory system and other organ systems. Several studies have investigated the underlying mechanisms of biological response to air pollutants using conventional techniques, but there is a lack of research on the effects of air pollution at the cellular level. This study developed a dual system that combines PM (particulate matter <2.

View Article and Find Full Text PDF

From indoors to outdoors: Impact of waste anesthetic gases on occupationally exposed professionals and related environmental hazards - a narrative review and update.

Environ Toxicol Pharmacol

December 2024

São Paulo State University (UNESP), Medical School, Division of Anesthesiology, GENOTOX Lab., Botucatu, São Paulo, Brazil. Electronic address:

Waste anesthetic gases (WAGs) are trace-concentration inhaled anesthetics that exist worldwide because they are released into the ambient air of operating rooms (ORs) and post-anesthesia care units. WAGs cause indoor contamination, especially in ORs lacking proper scavenging systems, and occupational exposure, while promoting climate change through greenhouse gas/ozone-depleting effects. Despite these controversial features, WAGs continue to pose occupational health hazards.

View Article and Find Full Text PDF

Radon (Rn) and thoron (Rn) were reported as the highest contributors to natural radiation received by humans. Furthermore, radon has been stated as the second-highest cause of lung cancer. The concentrations of U and Th (the parent nuclide of radon and thoron, respectively) in nature vary with geological conditions and can be enhanced by human activities.

View Article and Find Full Text PDF

Background: Dentists can be exposed to dust and nanoparticles from teeth, dental composites, and metal alloys generated during dental procedures, and exposure to dust can cause respiratory diseases, including pulmonary fibrosis. The authors describe mortality from nonmalignant respiratory diseases (NMRDs) among dentists in the United States.

Methods: The authors submitted information on US dentists who died from 1979 through 2018 to a centralized US death records database to obtain underlying causes of death.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?