A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Protection against large-volume regurgitated fluid aspiration by the ProSeal laryngeal mask airway. | LitMetric

Protection against large-volume regurgitated fluid aspiration by the ProSeal laryngeal mask airway.

Acta Anaesthesiol Taiwan

Department of Anesthesiology, Chang Gung Memorial Hospital-Linkou, 5 Fu-Shin 1st Street, Kwei-Shan, Taoyuan, Taiwan, R.O.C.

Published: March 2008

The ProSeal laryngeal mask airway (PLMA) is designed to protect the airway from regurgitated fluid. However, successful channeling of large volumes of regurgitated fluid by PLMA is rarely reported. This case report states that a large volume of regurgitated fluid was successfully channeled by a PLMA. The patient was a healthy 43-year-old male, properly fasted, undergoing transurethral cystolithotomy under general anesthesia with a correctly-placed PLMA. Unexpectedly, a large volume of regurgitated fluid (> 500 mL) spurted out from the PLMA esophageal drainage tube 2 hours after surgery. Careful gastric decompression was performed and airway toilet showed no evidence of aspiration of gastric contents. An endotracheal tube was then placed in lieu of the PLMA for airway maintenance. By the end of surgery, 1300 mL of fluid was drained through the gastric tube. Extubation was smooth and the patient had an uneventful recovery. Further radiological examination revealed the existence of an unrecognized vesicorectal fistula, which allowed the cystoscopic irrigation fluid to escape to the GI tract, resulting in massive gastric regurgitation. The patient underwent fistula repair a week later and was discharged without further difficulty. This is a unique clinical case report to show PLMA can be effective in preventing aspiration when massive passive regurgitation occurs. Strategies in the management of massive regurgitation during PLMA use are discussed.

Download full-text PDF

Source
http://dx.doi.org/10.1016/S1875-4597(08)60018-1DOI Listing

Publication Analysis

Top Keywords

regurgitated fluid
20
proseal laryngeal
8
laryngeal mask
8
mask airway
8
plma
8
case report
8
large volume
8
volume regurgitated
8
fluid
7
regurgitated
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!