A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Analysis and measurements of magnetic field exposures for healthcare workers in selected MR environments. | LitMetric

There are concerns about workers repeatedly exposed to magnetic fields exceeding regulatory limits with respect to modern magnetic resonance imaging (MRI). As a result, there is need for an ambulatory magnetic field dosimeter capable of measuring these fields in and around an MRI scanner in order to evaluate the regulatory guidelines and determine any underlying exposure risks. This study presents results of tri-axial measurements using an ambulatory magnetic field dosimeter worn by workers during normal working shifts. We recorded and analyzed magnetic field exposures in and around 1.5 T, 2 T, and 4 T magnets during routine patient procedures. The data was integrated and averaged over time and evaluated against the latest exposure standards. Time-varying magnetic fields occur when individuals move through spatially non-uniform static magnetic fields or during gradient-pulsed magnetic fields or a combination of both. Our previous numerical analysis shows that at certain positions surrounding the MRI scanner ends, such fields may induce current densities and electric fields that may exceed the relevant EU, ICNIRP, and IEEE standards. A high-speed acquisition version of the dosimeter measured gradient- pulsed fields at positions accessible by MRI workers near the scanner ends, and the results were evaluated and compared against the numerical simulations and the standards. Our measurements confirm that workers can be exposed to magnetic fields exceeding the guidelines at positions near the gradient coil ends during clinical imaging and a high degree of correlation exists with the numerical results. While the time-weighted average magnetic field exposures in 1.5 T, 2 T, and 4 T were all within the regulatory limits during static magnetic field measurements, the peak limits for the head can be exceeded in some circumstances. This study presents a small number of routine shifts of data that provide indicative results of magnetic field exposure in real situations.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TBME.2007.913410DOI Listing

Publication Analysis

Top Keywords

magnetic field
28
magnetic fields
20
magnetic
13
field exposures
12
fields
9
exposed magnetic
8
fields exceeding
8
regulatory limits
8
ambulatory magnetic
8
field dosimeter
8