The article narrates on newly developed techniques for the detection of dichlorpinacolin (DCP) in the working zone air. The study was performed on the chromatograph 'Tsvet 164' equipped with a detector of recombination stability (RCS), using Interton-Super as absorbent with phases SE-30.3% (1), OV-17.3% (II), and Carbowax 1500, 5% (III). The lower threshold for determining DCP in the sample volume was 0.001 mkg, in the air--2.5 mu/m3, and in the water--0.025 m/l. The concentration range in the air: 2.5-40.0 mu/m3 (I,III), 2.5-30 mu/m3 (II); in the water: 0.025-0.4 mu/l (I, III) and 0.025-0.3 mu/l (II). Quantitative assessments were performed through the absolute calibrating technique.

Download full-text PDF

Source

Publication Analysis

Top Keywords

[gas-chromatographic analysis
4
analysis dichloropinacoline
4
dichloropinacoline air
4
air work
4
work area
4
area water]
4
water] article
4
article narrates
4
narrates newly
4
newly developed
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!