Roller pumps are widely used for cardiopulmonary bypass in developing nations by virtue of proven safety during several years of institutional use and cost effectiveness. However, careful adjustment of roller occlusion is needed because they are known to cause spallation, tubing wear, and the occasional incident of rupture of tubing in the extracorporeal circuit. Rupture of polyvinylchloride tubing in the pump raceway during repair of a ventricular septal defect in a 4-year-old child is discussed. The event was managed by exclusion and replacement of the defective tubing during a short period of arrest. Use of an inappropriate boot pump and failure to detect its inclusion in the bypass circuit was a significant departure from protocol. However, because occlusion settings and duration of perfusion were within acceptable limits, a manufacturing flaw could also have contributed to tubing failure, and the event may or may not have been averted by the use of larger tubing. In conclusion, this incident reiterates the need for adherence to established protocol during assembly of the pump and draws attention to the fact that tubing integrity is not a guarantee and vigilance is warranted to handle its failure.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4680661PMC

Publication Analysis

Top Keywords

tubing
8
cardiopulmonary bypass
8
rupture extra-corporeal
4
extra-corporeal circuit
4
circuit tubing
4
tubing cardiopulmonary
4
bypass roller
4
roller pumps
4
pumps cardiopulmonary
4
bypass developing
4

Similar Publications

Aim: To compare the microleakage in class V cavities restored with Activa Bioactive Restorative, Activa Pronto, and nanohybrid composite.

Materials And Methods: Standardized class V cavity preparations (mesiodistal: 3 mm; occlusocervical: 2 mm; axial depth: 1 mm) were made on the buccal surface of 60 extracted intact maxillary premolar teeth. The preparations were divided into three experimental groups ( = 20) depending on the restorative material used.

View Article and Find Full Text PDF

Objective: Recent advancements in chest tube technologies have gained interest for their ability to enhance postoperative recovery via reduction of retained blood syndrome after cardiothoracic surgery. The present study investigates the effect of the Centese Thoraguard automated line-clearance chest tube system on postoperative pain and recovery after cardiac surgery.

Methods: This was a single-center retrospective review of 1771 adult patients undergoing nonemergency cardiac surgery between January 2021 and December 2022.

View Article and Find Full Text PDF

Background: Colorectal cancer (CRC) is the second-leading cause of cancer-related deaths. Curcumin has been reported to have suppressive effects in CRC and to address the physiological limitations of curcumin, a chemically synthesized curcuminoid analog, known as (2E,6E)-2,6-Bis (2,3-Dimethoxy benzylidine) cyclohexanone (DMCH), was developed and the anti-metastatic and anti-angiogenic properties of DMCH in colorectal cell line, SW620 were examined.

Methods: The anti-metastatic effects of DMCH were examined in the SW620 cell line by scratch assay, migration, and invasion assay, while for anti-angiogenesis properties of the cells, the mouse aortic ring assay and Human Umbilical Vein Endothelial Cells (HUVEC) assay were conducted.

View Article and Find Full Text PDF

The Effect of Extracorporeal Membrane Oxygenation on the Pharmacokinetics of Dexmedetomidine Hydrochloride.

J Cardiothorac Vasc Anesth

December 2024

Department of Critical Care Medicine, Shanghai General Hospital of Nanjing Medical University, Shanghai, 200080, China; Department of Critical Care Medicine, Shanghai General Hospital, Shanghai Jiao Tong University, School of Medicine, Shanghai, 200080, China. Electronic address:

Objectives: Our objective was to explore the effects of extracorporeal membrane oxygenation (ECMO) on the pharmacokinetics of dexmedetomidine hydrochloride via vitro and in vivo experiments DESIGN: A single-center animal investigation.

Setting: An experimental animal facility in a tertiary hospital.

Participants: Eighteen male Landrace pigs.

View Article and Find Full Text PDF

Oil recovery and heat transfer performance of polyurethane sponges coated with 3D carbon nano networks.

J Hazard Mater

December 2024

Center for Membrane Separation and Water Science & Technology, College of Chemical Engineering, Zhejiang University of Technology, Hangzhou 310014, China.

Heatable super hydrophobic polyurethane (PU) sponges (S-GNS/CNT/PVA@PU) containing three-dimensional (3D) carbon nano-networks (CNNs) coatings made from two-dimensional (2D) expanded graphite nano-sheets (GNS) bridged by one-dimensional (1D) carbon nano-tubes (CNT) were constructed using polyvinyl alcohol (PVA) as binder, in which light and/or electric energy could be rapidly converted into heat to reduce the viscosity of spilled heavy oils, resulting in greatly increased oil. Their heavy oil recovery rate could reach 792 kg/(m·h) under combined light and Joule heating of 1 sun and 5 V. Surface heat dissipating coefficient Ks, heat dissipating index n, and surface heat absorption capacity Cs were studied relating to sizes and shapes of surface heating fields under varied heating modes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!