A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Quantitative measurement of hypertrophic scar: intrarater reliability, sensitivity, and specificity. | LitMetric

The comparison of scar evaluation over time requires measurement tools with acceptable intrarater reliability and the ability to discriminate skin characteristics of interest. The objective of this study was to evaluate the intrarater reliability and sensitivity and specificity of the Cutometer, the Mexameter, and the DermaScan C relative to the modified Vancouver Scar Scale (mVSS) in patient-matched normal skin, normal scar (donor sites), and hypertrophic scar (HSc). A single investigator evaluated four tissue types (severe HSc, less severe HSc, donor site, and normal skin) in 30 burn survivors with all four measurement tools. The intraclass correlation coefficient (ICC) for the Cutometer was acceptable (> or =0.75) for the maximum deformation measure for the donor site and normal skin (>0.78) but was below the acceptable range for the HSc sites and all other parameters. The ICC for the Mexameter erythema (>0.75) and melanin index (>0.89) and the DermaScan C total thickness measurement (>0.82) were acceptable for all sites. The ICC for the total of the height, pliability, and vascularity subscales of the mVSS was acceptable (0.81) for normal scar but below the acceptable range for the scar sites. The DermaScan C was clearly able to discriminate HSc from normal scar and normal skin based on the total thickness measure. The Cutometer was less discriminating but was still able to discriminate HSc from normal scar and normal skin. The Mexameter erythema index was not a good discriminator of HSc and normal scar. Receiver operating characteristic curves were generated to establish the best cutoff point for the DermaScan C total thickness and the Cutometer maximum deformation, which were 2.034 and 0.387 mm, respectively. This study showed that although the Cutometer, the DermaScan C, and the Mexameter have measurement properties that make them attractive substitutes for the mVSS, caution must be used when interpreting results since the Cutometer has a ceiling effect when measuring rigid tissue such as HSc and the Mexameter erythema index does not discriminate normal scar from HSc.

Download full-text PDF

Source
http://dx.doi.org/10.1097/BCR.0b013e3181710869DOI Listing

Publication Analysis

Top Keywords

normal scar
24
normal skin
20
intrarater reliability
12
mexameter erythema
12
total thickness
12
hsc normal
12
scar
11
normal
11
hsc
9
hypertrophic scar
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!