Mean position tracking of respiratory motion.

Med Phys

Department of Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, Michigan 48109, USA.

Published: February 2008

Modeling and predicting tumor motion caused by respiration is challenging due to temporal variations in breathing patterns. Treatment approaches such as gating or adaptive bed adjustment/ alignment may not require full knowledge of instantaneous position, but might benefit from tracking the general trend of the motion. One simple method for tracking mean tumor position is to apply moving average filters with window sizes corresponding to the breathing periods. Yet respiratory motion is only semiperiodic, so such methods require reliable phase estimation, which is difficult in the presence of noise. This article describes a robust method to track the mean position of respiratory motion without explicitly estimating instantaneous phase. We form a state vector from the respiration signal values at the current instant and at a previous time, and fit an ellipse model to training data. Ellipse eccentricity and orientation potentially capture hysteresis in respiratory motion. Furthermore, we provide two recursive online algorithms for real time mean position tracking: a windowed version with an adaptive window size and another one with temporal discounting. We test the proposed method with simulated breathing traces, as well as with real time-displacement (RPM, Varian) signals. Estimation traces are compared with retrospectively generated moving average results to illustrate the performance of the proposed approach.

Download full-text PDF

Source
http://dx.doi.org/10.1118/1.2825616DOI Listing

Publication Analysis

Top Keywords

respiratory motion
16
position tracking
8
moving average
8
motion
6
position
5
respiratory
4
tracking respiratory
4
motion modeling
4
modeling predicting
4
predicting tumor
4

Similar Publications

Comparing the Robustness of Intensity-modulated Proton Therapy and Proton-arc Therapy Against Interplay Effects of 4D Robust-optimised Plans for Lung Stereotactic Body Radiotherapy.

Clin Oncol (R Coll Radiol)

January 2025

Department of Radiation Oncology, Cancer Center, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China; Department of Radiotherapy Physics & Technology, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China.

Aims: To assess the robustness of 4D-optimised IMPT and PAT plans against interplay effects in non-small cell lung cancer (NSCLC) patients with respiratory motion over 10 mm, and to provide insights into the use of proton-based stereotactic body radiotherapy (SBRT) for lung cancer with significant tumour movement.

Materials And Methods: Fourteen patients with early-stage NSCLC and tumour motion >10 mm were selected. Three hypofraction regimens were generated using 4D robust optimisation with the IMPT and PAT techniques.

View Article and Find Full Text PDF

Free-Breathing Respiratory Triggered High-Pitch Lung CT: Insights From Phantom and Patient Scans.

Invest Radiol

January 2025

From the Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany (A. Schwarz, A. Simon, A.M.); Siemens Healthineers AG, Forchheim, Germany (A. Schwarz, C.H., J.D., A. Simon); Institute for Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany (F.K.W., S.G., M.S.); and Institut for Radiology, Pediatric and Neuroradiology, Helios Hospital, Schwerin, Germany (H.-J.R.).

Objective: Respiratory motion can affect image quality and thus affect the diagnostic accuracy of CT images by masking or mimicking relevant lung pathologies. CT examinations are often performed during deep inspiration and breath-hold to achieve optimal image quality. However, this can be challenging for certain patient groups, such as children, the elderly, or sedated patients.

View Article and Find Full Text PDF

Respiratory motion phantoms can be used for evaluation of CT imaging technologies such as motion artifact reduction algorithms and deformable image registration. However, current respiratory motion phantoms do not exhibit detailed lung tissue structures and thus do not provide a realistic testing environment. This paper presents PixelPrint, a method for 3D-printing deformable lung phantoms featuring highly realistic internal structures, suitable for a broad range of CT evaluations, optimizations, and research.

View Article and Find Full Text PDF

Purpose: This study aims to develop an accurate image registration framework for personalized respiratory motion modeling.

Methods: The proposed framework incorporates longitudinal data through a two-stage transfer learning approach. In the first stage, transfer learning is employed on longitudinal data collected from the same device.

View Article and Find Full Text PDF

Background: Dynamic chest radiography (DCR) is useful for detecting preoperative pleural adhesions, predicting operation time and blood loss, and determining the surgical approach. However, since DCR evaluations are subjective, an objective index was needed. Therefore, we focused on the low motion area (LMA) ratio derived from the objective data obtained through DCR.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!