Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: To evaluate the feasibility of whole body imaging using a 3 Tesla magnetic resonance scanner without a contrast agent, and to study the prevalence of abnormal findings among a cohort of asymptomatic doctors.
Design: Prospective study.
Setting: Private hospital, Hong Kong.
Participants: A total of 132 asymptomatic medical doctors (111 men, 21 women), with a mean age of 56 (range, 38-82) years, volunteered for the study. They underwent corresponding whole body imaging at our hospital between October 2005 and February 2006. Imaging involved a 3 Tesla magnetic resonance scanner with 32 channels, parallel imaging, Total Imaging Matrix technology, a maximum gradient amplitude of 40 mT/m and a slew rate of 200 mT/m/ms (Magnetom Tim Trio, Siemens Medical Solution, Erlangen, Germany). The use of matrix coils enabled coverage of the whole body. No contrast agent was used.
Main Outcome Measures: Detection of abnormalities in asymptomatic, apparently healthy adults.
Results: All examinations were completed successfully. The mean scan time per subject was 33 (standard deviation, 4) minutes. All subjects tolerated the examination well and overall imaging quality was satisfactory. A total of 124 (94%) subjects had positive findings, of whom 24 (18%) had further workup. Five (4%) subjects were found to have tumours, of which two (1.5%) were proven malignant. Our cancer detection rate was comparable to that of other reported whole body screening studies using contrast magnetic resonance imaging and positron emission tomography.
Conclusion: We demonstrated the feasibility of performing whole body imaging in 30 minutes, using 32-channel magnetic resonance imaging at 3 Tesla without a contrast agent or any ionising radiation.