A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Determination of free and reversibly-bound sulfite in selected foods by high-performance liquid chromatography with fluorometric detection. | LitMetric

A rapid and accurate method for measuring low part-per-million levels of free and reversibly-bound sulfites in selected foods by using high-performance liquid chromatography (HPLC) with fluorometric detection was developed. Sulfites were extracted with sodium tetrachloromercurate solution and determined by HPLC-fluorescence spectrometry. During the HPLC analysis, the sample extract was reacted with sodium hydroxide to liberate the reversibly-bound sulfite and subsequently separated from other interferences by a size exclusion column. The effluent was then reacted with o-phthalaldehydelammonium chloride reagent to form a fluorescing 1-sulfonatoisoindole derivative and analyzed by a fluorescence detector. The method has been applied to a variety of foods and food products, with no significant interference encountered in matrixes such as soy products, cabbage, broccoli, brassica, ginger, fungus, mushroom, mandarin peel, potato chips, and biscuits. It was shown to have a broad linear range of 0.01 to 0.4 mg/L as SO2. The spike recoveries of sodium sulfite, sodium metabisulfite, and formaldehyde-sodium bisulfite adduct at the 5 to 10 mg/kg level in the tested food matrix were within 80-120%, and the limit of detection was 5 mg/kg. Laboratory of Government Chemist Reference Material LGC7111 (potato powder) was used to assess the accuracy of the method. The expanded measurement uncertainty of the method at 95% confidence level was estimated to be 17%.

Download full-text PDF

Source

Publication Analysis

Top Keywords

free reversibly-bound
8
reversibly-bound sulfite
8
selected foods
8
foods high-performance
8
high-performance liquid
8
liquid chromatography
8
fluorometric detection
8
determination free
4
sulfite selected
4
chromatography fluorometric
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!