Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A rapid and accurate method for measuring low part-per-million levels of free and reversibly-bound sulfites in selected foods by using high-performance liquid chromatography (HPLC) with fluorometric detection was developed. Sulfites were extracted with sodium tetrachloromercurate solution and determined by HPLC-fluorescence spectrometry. During the HPLC analysis, the sample extract was reacted with sodium hydroxide to liberate the reversibly-bound sulfite and subsequently separated from other interferences by a size exclusion column. The effluent was then reacted with o-phthalaldehydelammonium chloride reagent to form a fluorescing 1-sulfonatoisoindole derivative and analyzed by a fluorescence detector. The method has been applied to a variety of foods and food products, with no significant interference encountered in matrixes such as soy products, cabbage, broccoli, brassica, ginger, fungus, mushroom, mandarin peel, potato chips, and biscuits. It was shown to have a broad linear range of 0.01 to 0.4 mg/L as SO2. The spike recoveries of sodium sulfite, sodium metabisulfite, and formaldehyde-sodium bisulfite adduct at the 5 to 10 mg/kg level in the tested food matrix were within 80-120%, and the limit of detection was 5 mg/kg. Laboratory of Government Chemist Reference Material LGC7111 (potato powder) was used to assess the accuracy of the method. The expanded measurement uncertainty of the method at 95% confidence level was estimated to be 17%.
Download full-text PDF |
Source |
---|
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!