Purpose: To evaluate the success of lysis and clinical outcomes in patients treated with ultrasound (US)-accelerated thrombolysis for deep vein thrombosis (DVT).
Materials And Methods: Forty-seven patients with 53 cases of DVT were treated with US-accelerated thrombolysis at eight centers in the United States. Sixty percent of the occlusions were in the lower extremity, 36% were in the upper extremity, and 4% were hepatic. The clot was acute (< or =14 days) in 47% of cases, subacute (15-28 d) in 8%, chronic (>28 d) in 17%, acute-on-chronic in 17%, and not specified in 11%. Patients were treated with urokinase (UK), tissue plasminogen activator (tPA), recombinant plasminogen activator (rPA), or tenecteplase.
Results: Complete lysis (> or =90%) was seen in 37 of 53 cases (70%) and overall lysis (complete plus partial) was seen in 48 (91%). No lysis occurred in five cases (9%), four of which were chronic. The median thrombolysis infusion time was 22.0 hours. Major complications (hematoma at site of earlier surgery) occurred in only two patients (3.8%), with no incidence of intracranial or retroperitoneal hemorrhage. US-accelerated thrombolysis exhibited comparable or better lysis with a lower average drug dose and shorter median treatment times than reported in the National Venous Registry and a more recently published study of standard catheter-directed thrombolysis.
Conclusions: US-accelerated thrombolysis was shown to be a safe and efficacious treatment for DVT in this multicenter experience. The addition of US reduces total infusion time and provides a greater incidence of complete lysis with a reduction in bleeding rates.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jvir.2007.11.023 | DOI Listing |
J Vasc Surg
August 2015
Department of Surgery, VU University Medical Center, Amsterdam, The Netherlands; Department of Physiology, VU University Medical Center, Amsterdam, The Netherlands. Electronic address:
Background: The addition of local ultrasound (US) with a contrast agent to standard intra-arterial thrombolysis can accelerate the thrombolytic treatment of stroke and myocardial infarction. The contrast agent consists of microsized gas-filled bubbles that collapse when exposed to US, causing destabilization of the clot and making the clot surface more susceptible to fibrinolytics. In this study, we investigated the effect of additional US and microbubbles on standard low-dose intra-arterial thrombolysis in a porcine model of extensive peripheral arterial occlusion.
View Article and Find Full Text PDFDiagn Interv Radiol
January 2014
Department of Cardiovascular Surgery, Memorial Ataşehir Hospital, İstanbul, Turkey.
Purpose: We aimed to evaluate the efficacy and feasibility of ultrasonography (US)-accelerated catheter-directed thrombolysis for the treatment of deep venous thrombosis.
Materials And Methods: A total of 26 patients with deep venous thrombosis were prospectively selected for thrombolysis. Overall, 80.
J Vasc Interv Radiol
November 2012
Baptist Cardiac and Vascular Institute, Division of Vascular and Interventional Radiology, Miami, FL, USA.
Purpose: To compare the thrombolytic efficacy and safety of standard catheter-directed thrombolysis (CDT) and ultrasound (US)-accelerated thrombolysis (UAT) for the treatment of iliofemoral deep vein thrombosis (DVT).
Materials And Methods: All medical records of patients who underwent CDT or UAT for DVT between June 2004 and October 2011 at a single tertiary care center were reviewed. Target vein patency was graded according to a reporting standard by an independent interventional radiologist.
Cardiovasc Intervent Radiol
April 2012
Department of Vascular Surgery, St. Antonius Hospital, Koekoekslaan 1, 3435 CM Nieuwegein, The Netherlands.
Purpose: This article reports the 30-day technical and clinical outcome of ultrasound (US)-accelerated thrombolysis in patients with aortofemoral arterial thromboembolic obstructions.
Methods: A prospective cohort study was conducted from December 2008 to December 2009 of patients who were treated with US-accelerated thrombolysis for thromboembolic obstructions of aortofemoral arteries or bypasses. Urokinase was infused in a dosage of 100,000 IU per hour.
Expert Rev Neurother
February 2011
Cerebrovascular Unit, Hospital de São José, Centro Hospitalar de Lisboa Central, Lisbon, Portugal.
Achieving rapid reperfusion transcranial color-coded duplex is the critical issue in acute stroke treatment. Ultrasound (US) generates negative pressure waves that are associated with an increase in either intrinsic or intravenous tissue plasminogen activator (tPA)-induced fibrinolytic activity. Higher rates of tPA-induced arterial recanalization, associated with a trend towards better functional outcome, have been safely achieved by using high-frequency US.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!