A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Calibration of laryngeal endoscopic high-speed image sequences by an automated detection of parallel laser line projections. | LitMetric

High-speed laryngeal endoscopic systems record vocal fold vibrations during phonation in real-time. For a quantitative analysis of vocal fold dynamics a metrical scale is required to get absolute laryngeal dimensions of the recorded image sequence. For the clinical use there is no automated and stable calibration procedure up to now. A calibration method is presented that consists of a laser projection device and the corresponding image processing for the automated detection of the laser calibration marks. The laser projection device is clipped to the endoscope and projects two parallel laser lines with a known distance to each other as calibration information onto the vocal folds. Image processing methods automatically identify the pixels belonging to the projected laser lines in the image data. The line detection bases on a Radon transform approach and is a two-stage process, which successively uses temporal and spatial characteristics of the projected laser lines in the high-speed image sequence. The robustness and the applicability are demonstrated with clinical endoscopic image sequences. The combination of the laser projection device and the image processing enables the calibration of laryngeal endoscopic images within the vocal fold plane and thus provides quantitative metrical data of vocal fold dynamics.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.media.2007.12.007DOI Listing

Publication Analysis

Top Keywords

vocal fold
16
laryngeal endoscopic
12
laser projection
12
projection device
12
image processing
12
laser lines
12
calibration laryngeal
8
image
8
high-speed image
8
image sequences
8