Background: The pulmonary veins (PVs) are topographically complex and motile, so angiographic visualization of the PVs anatomy is limited. An imaging technique that accurately portrays the pulmonary vein (PV) anatomy would be valuable during and after catheter ablation procedures.
Purpose: We investigated whether three-dimensional (3D) intracardiac echocardiography (ICE) can visualize radiofrequency (RF)-induced tissue changes after PV isolation.
Methods: We performed 3D ICE studies with a 9F, 9-MHz ICE catheter after segmental or extended PV isolation. The ICE catheter was placed 3-4 cm inside the PV ostium and mounted onto a pullback device. Sequential two-dimensional (2D) images of the full length of the vein were obtained in 0.3 mm steps with cardiac and respiratory cycle gating. Each image was fed into a computer, and the aggregate data set was reconstructed into a 3D, full-motion image. RF lesion location and lesion size were studied on 67 pullback images from 29 patients.
Results: The 2D and 3D reconstruction was possible for 27 left superior PVs, 13 left inferior PVs, 26 right superior PVs, and one right inferior PV. The ablation site was identified 3-7 mm inside the PV ostium, and a 1/2 - 4/5 circumferential area was ablated with no clinically relevant stenosis. No significant differences were found on the ablated area or ablation site between segmental and extensive PV isolation.
Conclusion: The 2D and 3D ICE of the PVs provides detailed anatomical information of the proximal PVs, and RF-induced tissue changes in the PV wall can be visualized by ICE.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1540-8159.2008.01009.x | DOI Listing |
Stem Cell Rev Rep
January 2025
Institute of Biophysics, Chinese Academy of Sciences, Beijing, 100101, China.
Background: The hypobaric hypoxic atmosphere can cause adverse reactions or sickness. The purpose of this study was to explore the preventive effect and mechanism of human umbilical cord mesenchymal stem cells (hUC-MSCs) on acute pathological injury in mice exposed to high-altitude.
Methods: We pretreated C57BL/6 mice with hUC-MSCs via the tail vein injection, and then the mice were subjected to hypobaric hypoxic conditions for five days.
J Arthroplasty
January 2025
Department of Orthopedic Surgery, NYU Langone Health, 301 E 17th St, New York, NY, USA, 10010. Electronic address:
Background: Despite advances in surgical techniques and postoperative prophylactic protocols, venous thromboembolism (VTE) events remain an important source of morbidity following total hip arthroplasty (THA). Prior research in cardiology and other surgical fields has suggested that statin medications may have a protective effect against VTE. Our study aimed to: 1) Assess if preoperative statin use was associated with decreased rates of VTE following THA, and 2) conduct a subgroup analysis of statin intensity and VTE events.
View Article and Find Full Text PDFRev Port Cardiol
January 2025
Cardiology Department, Hospital Santa Cruz, Centro Hospitalar Lisboa Ocidental, Lisbon, Portugal.
Introduction And Objectives: Pulmonary vein (PV) isolation is one of the cornerstones of rhythm-control therapy for symptomatic atrial fibrillation (AF) patients. Pulsed field ablation (PFA) is a novel ablation modality that involves the application of electrical pulses causing cellular death, and it has preferential tissue specificity. In this study, we aimed to share a one-year single center experience of AF ablation with PFA.
View Article and Find Full Text PDFVet Med Sci
March 2025
Department of Veterinary Medicine, National Chiayi University, Chiayi City, Taiwan.
This case report highlights a potential vaccine safety concern associated with the Pseudorabies virus (PRV) live vaccine, which warrants further investigation for comprehensive understanding. Vaccine-induced immune thrombotic thrombocytopenia (VITT), a novel syndrome of adverse events following adenovirus vector COVID-19 vaccines, was observed after vaccination with Zoetis PR-VAC PLUS. This led to a 100% morbidity and high mortality among PRV-free Danish purebred pigs from Danish Genetics Co.
View Article and Find Full Text PDFPacing Clin Electrophysiol
January 2025
Department of Cardiology, Saitama Medical University, International Medical Center, Hidaka, Saitama, Japan.
Background: The IntellaNav MiFi OI catheter (MiFi) is equipped with a sensor for local impedance (LI) monitoring and three mini-electrodes. In this study, we investigated the target LI values for a successful pulmonary vein isolation (PVI) under the pacing and ablation technique using the MiFi catheter.
Methods: Twenty-seven patients underwent PVI using the MiFi catheter under mini electrode pacing from the MiFi catheter.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!