First-pass radionuclide ventriculography followed by myocardial SPECT with technetium-99m methoxy isobutyl isonitrile (Tc-99m MIBI) was performed on 12 patients with suspected coronary artery disease at rest and during exercise. Left ventricular wall motion and myocardial perfusion were assessed simultaneously and compared on a segment-by-segment basis. Segmental agreement between Tc-99m MIBI and Tl-201 with regard to the presence of perfusion defects was 95% (57/60) at rest and 93% (37/40) during exercise. With respect to the assessment of myocardial ischemia and/or infarction, abnormalities in regional wall motion agreed with the presence of myocardial perfusion defects in 18 out of 21 segments (86%). Simultaneous evaluation of regional wall motion and myocardial perfusion by Tc-99m MIBI may provide useful information for the assessment of myocardial ischemia.

Download full-text PDF

Source
http://dx.doi.org/10.1253/jcj.55.1192DOI Listing

Publication Analysis

Top Keywords

wall motion
16
myocardial perfusion
16
motion myocardial
12
tc-99m mibi
12
left ventricular
8
ventricular wall
8
rest exercise
8
technetium-99m methoxy
8
methoxy isobutyl
8
isobutyl isonitrile
8

Similar Publications

: This study explores how thoracic orientation affects lung pressure and injury outcomes from shock waves, building on earlier research that suggested human posture impacts injury severity. : A layered finite element model of the chest was constructed based on the Chinese Visual Human Dataset (CVH), including the rib and intercostal muscle layers. The dynamic response of the chest under 12 different angle-oriented shock waves under incident pressures of 200 kPa and 500 kPa was calculated.

View Article and Find Full Text PDF

Background: Myocardial injury after noncardiac surgery (MINS) is associated with an increased incidence of cardiac morbidity and mortality. Little is known about how these patients are managed.

Methods: We performed a single-centre retrospective chart review of patients referred to a postoperative clinic with the diagnosis of MINS.

View Article and Find Full Text PDF

Correlated spin-wave generation and domain-wall oscillation in a topologically textured magnetic film.

Nat Mater

January 2025

Condensed Matter Physics and Materials Science Division, Brookhaven National Laboratory, Upton, NY, USA.

Spin waves, or magnons, are essential for next-generation energy-efficient spintronics and magnonics. Yet, visualizing spin-wave dynamics at nanoscale and microwave frequencies remains a formidable challenge due to the lack of spin-sensitive, time-resolved microscopy. Here we report a breakthrough in imaging dipole-exchange spin waves in a ferromagnetic film owing to the development of laser-free ultrafast Lorentz electron microscopy, which is equipped with a microwave-mediated electron pulser for high spatiotemporal resolution.

View Article and Find Full Text PDF

Computational modeling of cardiac hemodynamics including chordae tendineae, papillaries, and valves dynamics.

Comput Biol Med

January 2025

LaBS, Dipartimento di Chimica, Materiali e Ingegneria Chimica "Giulio Natta", Politecnico di Milano, Piazza Leonardo da Vinci 32, Milan, 20133, Italy. Electronic address:

In the context of dynamic image-based computational fluid dynamics (DIB-CFD) modeling of cardiac system, the role of sub-valvular apparatus (chordae tendineae and papillary muscles) and the effects of different mitral valve (MV) opening/closure dynamics, have not been systemically determined. To provide a partial filling of this gap, in this study we performed DIB-CFD numerical experiments in the left ventricle, left atrium and aortic root, with the aim of highlighting the influence on the numerical results of two specific modeling scenarios: (i) the presence of the sub-valvular apparatus, consisting of chordae tendineae and papillary muscles; (ii) different MV dynamics models accounting for different use of leaflet reconstruction from imaging. This is performed for one healthy subject and one patient with mitral valve regurgitation.

View Article and Find Full Text PDF

This study evaluated the validity and reliability of the TecnoBody D-Wall system in assessing joint range of motion (ROM) during overhead squat movements in healthy individuals, using Kinovea as a reference tool for data comparison. A total of 29 participants (16 males, 13 females) with a mean age of 28.41 ± 6.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!