A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

An autonomous in situ detection system for radioactivity measurements in the marine environment. | LitMetric

An autonomous in situ detection system for radioactivity measurements in the marine environment.

Appl Radiat Isot

Hellenic Centre for Marine Research, Institute of Oceanography, P.O. Box 712, GR-19013 Anavyssos, Greece.

Published: October 2008

A new detection system named "KATERINA" is developed and applied for measuring marine radioactivity using NaI(Tl) as a crystal. This apparatus is designed for qualitative and quantitative radionuclide detection in the marine environment with maximum depth of deployment 400 m. A detailed study for the enclosure of the system and for the electronics development is performed. The system offers volumetric activities in Bq/m(3) using the marine efficiency calibration, which is measured by dilution of three reference sources ((99m)Tc, (137)Cs, and (40)K) in a special tank. The calibration procedures for energy, energy resolution and efficiency were analyzed with particular attention to the factors that affect the calibration parameters. The underwater detector is tested in the field for acquiring radon daughters ((214)Pb and (214)Bi) in a region where submarine groundwater discharge exists in the coastal zone.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.apradiso.2008.02.064DOI Listing

Publication Analysis

Top Keywords

detection system
8
marine environment
8
autonomous situ
4
situ detection
4
system
4
system radioactivity
4
radioactivity measurements
4
marine
4
measurements marine
4
environment detection
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!