A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Electrochemical, HPLC and electrospray ionization mass spectroscopic analyses of peroxycitric acid coexisting with citric acid and hydrogen peroxide in aqueous solution. | LitMetric

Electrochemical, HPLC and electrospray ionization mass spectroscopic analyses of peroxycitric acid coexisting with citric acid and hydrogen peroxide in aqueous solution.

Talanta

Department of Electronic Chemistry, Interdisciplinary Graduate School of Science and Engineering, Tokyo Institute of Technology, Mail Box G1-5, 4259 Nagatsuta, Midori-ku, Yokohama 226-8502, Japan.

Published: February 2008

We successfully determined the molecular structure of peroxycitric acid (PCA) coexisting in the aqueous equilibrium mixture with citric acid (CA; 1,2,3-tricarboxylic-2-hydroxy propane) and hydrogen peroxide (H(2)O(2)) by a combined use of reversed-phase HPLC (RP-HPLC), potentiometric, hydrodynamic chronocoulometric (HCC) and electrospray ionization mass spectroscopic (ESI-MS) methods. Firstly, the RP-HPLC was employed to separate CA, PCA and H(2)O(2) coexisting in the equilibrium mixture and the concentration of CA consumed (DeltaC(CA)) in the formation of PCA that was evidenced to be fairly stable during the RP-HPLC measurement was quantitatively measured based on the standard calibration curve of CA. Secondly, the total oxidant concentration (C(Ox)) corresponding to peroxycarboxylic (-COOOH) group in PCA in the equilibrium mixture was determined using potentiometric measurement. The ratio of C(Ox)/DeltaC(CA) was found to be 1.07, which indicates that only one -COOH group in CA molecule is oxidized to the corresponding -COOOH group in PCA molecule. Thirdly, using the HCC technique the diffusion coefficient of PCA, which could be electroreduced at a more positive potential by 1.0 V than the coexisting H(2)O(2), was independently measured as 0.3 x 10(-5)cm(2)s(-1) and at the same time, by considering DeltaC(CA) as the concentration of PCA, the number of electrons (n) required for the reduction of PCA was determined to be 2. The result obtained from RP-HPLC and HCC, i.e., n=2 which is equivalent to one -COOOH group in PCA, is in agreement with that obtained from the combination of RP-HPLC and potentiometric measurements. Finally, the structure of PCA was proposed to contain one -COOOH group with a molecular mass of 208 confirmed by negative ion ESI-MS method. A probable molecular structure of PCA was discussed.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2007.09.006DOI Listing

Publication Analysis

Top Keywords

-coooh group
16
equilibrium mixture
12
group pca
12
pca
11
electrospray ionization
8
ionization mass
8
mass spectroscopic
8
peroxycitric acid
8
citric acid
8
hydrogen peroxide
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!