Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The mechanical behavior of osteochondral defects was evaluated in this study with the intention of developing alternative procedures. Cylindrical pins (5.00 mm in diameter and in height) made of pHEMA hydrogel covered ultra-high molecular weight polyethylene (UHMWPE) or beta-tricalcium phosphate (beta-TCP) matrix were used. Ostoechondral defects were caused in the knees of adult dogs and the evaluation was carried out after a 9-month follow-up period. The mechanical behavior of the implants was evaluated by means of an indentation creep test that showed that the UHMWPE matrix maintained its viscoelastic behavior even after follow-up time, while the beta-TCP matrix osteochondral implants presented significant alterations. It is believed that the beta-TCP osteochondral implants were unable to withstand the load applied, causing an increase of complacency when compared to the UHMWPE osteochondral implants. Based on micro and macroscopic analysis, no significant wear was observed in either of the osteochondral implants when compared to the controls. However, morphological alterations, with fragmentation indices in the patella, were observed either due to friction with the hydrogel in the first postoperative months or due to forming of a dense conjunctive tissue. This wear mechanism caused on the counterface of the implant (patella) was observed, notwithstanding the osteochondral implant studied.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1525-1594.2008.00548.x | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!