The influence of the loading mode on the stress distribution on the connector region of metal-ceramic and all-ceramic fixed partial denture.

Artif Organs

Department of Metallurgy and Materials Engineering and Prosthesis and Dental Materials Department, Federal University of Rio de Janeiro, PEMM/COPPE/UFRJ, Rio de Janeiro, Brazil.

Published: April 2008

Studies pertaining to the mechanical behavior of fixed partial dentures (FPDs) frequently found the highest tensile stress values at the connector region when load is applied at the pontic central region. The connector region is considered the weakest point of the prosthesis with the greatest potential of fractures, regardless of the material used. This 2D finite element study compared the stress distribution on three-element all-ceramic and metal-ceramic FPDs with different loading conditions. Three FPD models were designed: (i) metal-ceramic FPD; (ii) all-ceramic FPD with the veneering porcelain only on the occlusal face; and (iii) all-ceramic FPD with the veneering porcelain on the occlusal and cervical face of the pontic. Loads of 100 N were applied following these simulations: (i) distributed on all working cusps; (ii) only on the abutment teeth; and (iii) only on the pontic. There is a significant change on the stress distribution and on the tensile stress values when the load configuration is changed. The stress distribution from the load applied on the abutments was significantly better compared with the other two load simulations. When the loads were applied on the pontic and distributed on all working cusps, the highest tensile stress values appeared on the cervical region of the connectors between the abutments and the pontic. However, when the load was applied on the abutment teeth, the maximum tensile stress value significantly decreased and was located on the occlusal region of the connectors. In fact, the load applied on the pontic region does not simulate the clinical situation. Studies using this load configuration have overestimated the connector regions as having the highest probability of failures.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1525-1594.2008.00544.xDOI Listing

Publication Analysis

Top Keywords

stress distribution
16
tensile stress
16
load applied
16
connector region
12
stress values
12
applied pontic
12
stress
8
fixed partial
8
highest tensile
8
all-ceramic fpd
8

Similar Publications

Background: The patellofemoral joint (PFJ) stress as a primary mechanical stimulus in the patellofemoral pain (PFP) etiology is affected by plantar pressure symmetry. This study evaluated how pain exacerbation affects rear foot eversion and plantar pressure distribution symmetry.

Method: Sixty women with PFP participated in this study.

View Article and Find Full Text PDF

Experimental investigation and finite element analysis on the durability of root-filled teeth treated with multisonic irrigation.

Dent Mater

January 2025

Minnesota Dental Research Center for Biomaterials and Biomechanics, School of Dentistry, University of Minnesota, Minneapolis, MN, USA. Electronic address:

Objective: This study compared the fracture load, stress distribution, and survival probability under cyclic loading of extensively restored teeth treated with multisonic irrigation with those treated with conventional instrumentation, with or without a post.

Methods: Mesial-occlusal-distal cavities were prepared in 30 human mandibular premolars. The teeth were randomly divided into 3 groups of 10 based on the endodontic and restorative procedures: (1) Root canal treatment (RCT) followed by resin composite restoration (control group), (2) RCT followed by a glass fiber post restoration (conventional group), and (3) minimal instrumentation plus multisonic irrigation followed by resin composite restoration (GW group).

View Article and Find Full Text PDF

Objective: Photopolymerized resin composites are widely used as dental filling materials. However, the shrinkage stress generated during photopolymerization can lead to marginal microcracks and eventual restoration failure. Accurate assessment of the stress evolution in dental restorations, particularly in complex cavity geometries, is critical for improving the performance and longevity of the dental filling materials.

View Article and Find Full Text PDF

This study evaluated the effect of wheat germ oil (WGO), Bacillus subtilis, and their combination on growth performance, immune response, nutrient digestibility, intestinal microbial, oxidative status, and gene expression in heat-stressed broilers. Four hundred one-day-old male Ross 308 broilers were distributed into five pens (20 birds/pen) in four experimental groups: a control (CON) without additives, WGO group fed diet with WGO at 200 mg.kg, BS group fed diet with B.

View Article and Find Full Text PDF

The cervical uncinate process is a unique structure of the cervical spine that undergoes significant changes in its morphological characteristics with age, and these changes may be related to osteoporosis. This study aimed to observe the distribution of cancellous bone in the cervical uncinate process and its morphological features using micro-computed tomography (Micro-CT) to gain a deeper understanding of the morphological characteristics of the uncinate microstructure. We performed Micro-CT scans on 31 sets of C3-C7 vertebrae, a total of 155 intact bone samples, and subsequently used the measurement software with the Micro-CT system to obtain parameters related to the cancellous bone of the uncinate process.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!