Background: Mechanical thrombolysis may effectively enhance the efficacy of thrombolysis for hyperacute ischemic stroke patients.
Purpose: To assess the feasibility and results of simple mechanical-based thrombolysis using microwire and microcatheter with adjuvant low-dose intraarterial (i.a.) urokinase (UK) for the treatment of hyperacute ischemic stroke.
Material And Methods: Nineteen consecutive patients with hyperacute proximal middle cerebral artery (MCA) occlusions treated by a standardized protocol using microwire and microcatheter for mechanical thrombus disruption with adjuvant i.a. UK were reviewed. Simple to-and-fro passages through the clot with the microwire and microcatheter followed by disruptions by a J- or pigtail-shaped wire tip with alternating small-dose injections of UK distal, within, and proximal to the clot were performed. The recanalization rates, post-thrombolysis hemorrhage, and clinical outcome (baseline and discharge National Institute of Health Stroke Scale [NIHSS], mortality, 3-month modified Rankin scale [mRS]) were evaluated.
Results: Recanalization was achieved in 18 of 19 patients (94.7%). The mean UK dose was 375,789 IU (range 130,000-580,000 IU). Two patients (10.5%) developed symptomatic hemorrhage. One of the hemorrhages included a patient who developed subarachnoid hemorrhage. Mortality rate was 15.8% (n = 3). The median baseline NIHSS scores showed improvement from 17 to 10 at presentation and discharge, respectively. At three months, good outcome was noted in 11 of 19 patients (57.9%, mRS 0-2).
Conclusion: Simple mechanical-based thrombolysis using microwire and microcatheter with adjuvant low-dose i.a. UK is safe and effective in achieving recanalization with good long-term outcome.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1080/02841850701819143 | DOI Listing |
Interv Neuroradiol
December 2024
Department of Radiology, Mayo Clinic, Rochester, MN, USA.
Background And Purpose: Mechanical thrombectomy (MT) has become the standard of care for treatment of acute ischemic stroke secondary to large vessel occlusion up to 24 h from the last known normal time. With ADAPT and SOLUMBRA techniques, classically, a large bore aspiration catheter is delivered over a microcatheter and microwire crossing the clot to perform thrombectomy. Recently, a novel macrowire (Colossus 035 in.
View Article and Find Full Text PDFInterv Neuroradiol
December 2024
Department of Neurology, Neurological Surgery and Radiology, Indiana University School of Medicine, Indianapolis, IN, USA.
Mechanical thrombectomy has become the cornerstone to achieve reperfusion in large vessel occlusion causing acute ischemic stroke. Since the advent of intracranial thrombectomy, the procedural setup has been to deliver aspiration catheter over microwire and microcatheter to the intracranial occlusion (ADAPT) or to deliver the stent-retriever through the microcatheter (SOLUMBRA) to perform thrombectomy. In both these techniques the quintessential aspect is crossing the clot/thrombus, which increases the chances of clot fragmentation or disruption.
View Article and Find Full Text PDFOper Neurosurg (Hagerstown)
July 2024
Department of Neurosurgery, University of Texas Health Science Center at San Antonio, San Antonio, Texas, USA.
Background And Importance: Giant aneurysms can present technical challenges during treatment with flow diversion including inability to access the aneurysm outflow directly. Encircling the aneurysm with a microwire/microcatheter has been well described; however, it can result in a twisted stent because of catheter twisting during the reduction maneuver, which, in turn, could lead to thromboembolic complications.
Case Presentation: Here, we describe a novel technique to manage the twist of the flow diverter in a giant internal carotid artery aneurysm using a combination of angioplasty and off-label placement of a balloon-mounted cardiac stent within the flow diverter.
J Neurointerv Surg
January 2025
Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, USA
J Neurointerv Surg
January 2025
Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona, USA
Transcirculation catheterization, also known as the retrograde approach, involves the navigation of a catheter or other endovascular device from one arterial circulation to the other (right to left, or anterior to posterior).1-4 We present a case of a complex vertebrobasilar junction aneurysm previously treated by bilateral vertebral artery deconstruction, precluding antegrade access (video 1). Following the creation of a protective occipital artery to posterior inferior cerebellar artery (PICA) bypass, the patient was treated with transcirculation placement of a Pipeline embolization device (PED).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!