Objective: To investigate the value of various MR imaging sequences for the assessment of articular cartilage and to determine the most optional sequence.
Methods: MR sagittal scanning of knee joints were performed in nine fresh bovine models. MR scan sequences consisted of TSE-T(1)WI, TSE-T(2)WI, TSE-PDWI, 3D-FFE-T(1)WI, 3D-BFFE, TSE-T(1)WI-SPIR, TSE-T(2)WI-SPIR, TSE-PDWI-SPIR, 3D-FFE-SPIR, 3D-FFE-WATS, 3D-FFE-MTC, 3D-BFFE-WATS. The signal noise ratio (SNR) and contrast noise ratio (CNR) between cartilage and adjacent tissue were calculated and compared. The knees of fifteen healthy volunteers were imaged with the selective MR sequences and the SNR, CNR and their efficiency were calculated and analyzed statistically.
Results: In bovine knee models, the cartilage SNR was higher in the sequences which attached SPIR, WATS and MTC than that of without these techniques. There was a statistically significant difference. The CNR between cartilage and adjacent tissue was also higher in the former. In healthy volunteers, the cartilage SNR was better in 3D-FFE-SPIR, 3D-FFE-WATS, 3D-BFFE-WATS. CNR between cartilage and bone, marrow, muscle, fat were better in 3D-FFE-SPIR, 3D-FFE-WATS, 3D-BFFE-WATS; CNR between cartilage and liquid was better in 3D-FFE-WATS, TSE-T2WI-SPIR, TSE-PDWI-SPIR; CNR between cartilage and meniscus, ligament was better in 3D-FFE-SPIR, 3D-BFFE-WATS, TSE-PDWI-SPIR. The SNR and CNR efficiency were higher in 3D-FFE-WATS, 3D-BFFE-WATS, 3D-FFE-SPIR. There was a statistical difference between these sequences and others (P < 0.01). The cartilage SNR and CNR between cartilage and bone, muscle of 3D-FFE-SPIR weren't significantly higher than that of 3D-FFE-WATS (P > 0.05); CNR between cartilage and liquid, marrow, fat were higher in 3D-FFE-WATS and significantly different than that of 3D-FFE-SPIR (P < 0.01).
Conclusion: Articular cartilage SNR and CNR between cartilage and its surrounding tissue are higher in sequences attached SPIR, WATS, so fat suppress technique should routinely be used in clinical cartilage examination. WATS has high scan speed and suppress the fat signal evenly, so it can substitute SPIR. 3D-FFE-WATS is one of the most sensitive sequences in showing cartilage shape and detecting its injury. The cartilage SNR, the CNR between cartilage and adjacent tissue and their efficiency are high in 3D-BFFE-WATS and it can be used in the clinical examination.
Download full-text PDF |
Source |
---|
Res Vet Sci
January 2025
Department of Veterinary Sciences, Veterinary Teaching Hospital "Mario Modenato", via Livornese snc, San Piero a Grado, Pisa, Italy.
CT arthrography (CTA) for evaluating cartilage defects would be beneficial in clinical practice. Since the contrast medium (CM) volume is often driven by operator experience, the aim was to evaluate the minimum volume of iodinated CM for CTA sufficient to identify iatrogenic cartilage defects in horse fetlock. The study was conducted on ex-vivo 32 distal limbs from adult horses collected at slaughter.
View Article and Find Full Text PDFJ Fish Biol
January 2025
Department of Medicine and Technological Innovation, University of Insubria, Varese, Italy.
Histochem Cell Biol
December 2024
School of Mechanical, Medical & Process Engineering, Queensland University of Technology, 60 Musk Ave/Cnr. Blamey St, Kelvin Grove, Brisbane, QLD, 4059, Australia.
Understanding the osteochondral junction, where non-mineralised cartilage and mineralised bone converge, is crucial for joint health. Current sample preparation techniques are insufficient for detailed spatial hyperspectral imaging analysis. Using the enhanced Kawamoto method, we used the super cryo embedding medium's temperature-dependent properties to transfer high-quality tissue samples onto slides for spatial imaging analysis.
View Article and Find Full Text PDFInt J Biomed Imaging
October 2024
Tehran Heart Center, Tehran University of Medical Sciences, Tehran, Iran.
Three-dimensional gradient-echo (3D-GRE) sequences provide isotropic or nearly isotropic 3D images, leading to better visualization of smaller structures, compared to two-dimensional (2D) sequences. The aim of this study was to prospectively compare 2D and 3D-GRE sequences in terms of key imaging metrics, including signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), glenohumeral joint space, image quality, artifacts, and acquisition time in shoulder joint images, using 1.5-T MRI scanner.
View Article and Find Full Text PDFJ ISAKOS
December 2024
Department of Orthopaedic Surgery and Bioengineering, University of Pittsburgh School of Medicine - UPMC, Pittsburgh, PA, 15213, United States. Electronic address: