Purpose: The purpose of this study is to compare the different effects of alveolar bone remolding due to retraction of anterior teeth by two types of anchorage mini-screw implant or regular maximum anchorage.
Methods: The sample comprised 26 orthodontic patients with upper dental alveolar bone protrusion and mild crowding. The treatment plan was to remove the four first bicuspids. 14 patients,3 males,11 females, aged 20-54 years old (mean: 25 years) were treated with implant anchorage to retract the maxillary anterior teeth. 12 patients, 1 male,11 females, aged 18-30 years old (mean: 21 years) were treated with regular maximum anchorage to retract maxillary anterior teeth. Lateral cephalograms of all patients were evaluated at two stages: pretreatment, post-treatment.The changes of the long axis of the anterior teeth and dental alveolar were measured.SPSS11.0 software package was used for statistical analysis.
Results: The cephalometric findings showed that the anterior teeth were retracted with implant anchorage significantly more than the maximum anchorage, there was no significant difference in the dental alveolar bone remolding between two groups. The first molars moved anteriorly slightly (less than 1mm) with implant anchorage, but significantly (3.08 mm) with regular maximum anchorage.
Conclusions: The maxillary anterior teeth are significantly retraced with the implant anchorage; the molars move mesially significantly less in the implant group than the maximum group. There are no significant differences in dental alveolar bone remolding between both groups. Support by Shanghai Leading Academic Discipline Project (Grant No.Y0203) and Research Fund of Science and Technology Committee of Shanghai Municipality (Grant No. 05B224).
Download full-text PDF |
Source |
---|
BMC Oral Health
January 2025
Department of Dental Implantology, Jinan Stomatological Hospital, Jinan, 250002, Shandong, People's Republic of China.
Objective: To study the biomechanical changes induced by differences in perioral force in patients with missing anterior maxillary teeth at rest via finite element analysis (FEA).
Methods: Using conical beam CT (CBCT) images of a healthy person, models of the complete maxillary anterior dental region (Model A) and maxillary anterior dental region with a missing left maxillary central incisor (Model B) were constructed. The labial and palatine alveolar bone and tooth surface of the bilateral incisor and cusp regions were selected as the application sites, the resting perioral force was applied perpendicular to the tissue surface, and the changes in maxillary stress and displacement after the perioral force was simulated were analyzed.
Eur J Dent
December 2024
Department of Preventive and Restorative Dentistry, College of Dental Medicine, University of Sharjah, Sharjah, United Arab Emirates.
Objective: This study compares the color change of non-vital anterior teeth after laser-activated bleaching and conventional walking bleaching technique.
Materials And Methods: Sixty extracted teeth were endodontically treated, stained in a black tea solution, and the baseline shade was measured using a spectrophotometer (Easyshade, VITA). Bleaching was done using either: internal bleaching with 35% HO (Opalescence Endo) and then tooth sealed for 5 days (Gr1), 35% HO (JW Next) for 7 minutes (Gr2), internal and external bleaching for 7 minutes (Gr3), diode laser-activated internal bleaching for 30 seconds (940 nm, continuous wave, 2 W, noncontact mode, 300 um, non-initiated tip), wait for 7 minutes, second laser application for 30 seconds, tooth sealed for 5 days (Gr4), diode laser-activated internal bleaching for 24 hours (Gr5), or diode laser-activated internal and external bleaching for 24 hours (Gr6) ( = 10).
J Indian Prosthodont Soc
January 2025
Department of Prosthodontics and Implantology, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, Tamil Nadu, India.
Aim: The purpose of this in vitro study was to compare the marginal fit of various three-dimensional (3D) printed and milled polymethylmethacrylate (PMMA) dental prostheses.
Settings And Design: The study was conducted in an in vitro study setting.
Materials And Methods: With a sample size of 45 for each fabrication method, this investigation compared the marginal fit of milled (Group 1) and 3D printed (Group 2) PMMA dental prostheses across different designs.
J Indian Prosthodont Soc
January 2025
Department of Substitutive Dental Sciences, College of Dentistry and Pharmacy, Buraydah Private Colleges, Buraydah, Saudi Arabia.
Aims: To assess the role of oral health literacy (OHL) in demand for oral healthcare services for missing teeth replacement among adult patients who are visiting the outpatient department of a teaching hospital, Andhra Pradesh, India.
Settings And Design: This cross-sectional study was conducted in a dental teaching institute, Andhra Pradesh, southern part of India.
Materials And Methods: Based on the inclusion and exclusion criteria, a sample of adult participants was selected through systematic random method from the patients who visited the outpatient department.
Turk J Orthod
December 2024
Government Dental College, Kozhikode, Faculty of Orthodontics and Dentofacial Orthopaedics, Kerala, India.
Objective: To investigate the effect of deferred timing of therapeutic extraction on the rate of space closure during en masse anterior retraction.
Methods: Twenty-six patients (aged 16-24 years) with bimaxillary protrusion, crowding <3 mm, requiring bilateral extraction of four first premolars were recruited. Permuted block randomization was done.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!