A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Minimally invasive imageless computer-navigated knee surgery: initial results. | LitMetric

Minimally invasive imageless computer-navigated knee surgery: initial results.

J Arthroplasty

Department of Orthopaedic Surgery, Sutherland Hospital, Sutherland NSW, Australia.

Published: April 2008

The combination of imageless computer-aided surgery (CAS) and minimally invasive surgery (MIS) for total knee arthroplasty (TKA) has not been reported. This study presents the initial 30 procedures in which imageless CAS was combined with MIS for TKA by the senior author. Coronal alignment of femoral and tibial components with respect to the mechanical axis of the lower limb was measured when patients could achieve full extension. Component position was acceptable for all implants. The mean coronal tibial alignment was 90.35 degrees (range, 88 degrees -93 degrees ) and mean coronal femoral alignment 90.10 degrees (range, 88 degrees -93 degrees ) to the mechanical axis. Tourniquet time averaged 90 minutes (range, 60-118 minutes). There was no significant reduction in tourniquet time with increasing familiarity with the technique. Our results demonstrate that CAS combined with MIS for TKA maintains the accuracy of component alignment despite the minimally invasive approach. These initial results demonstrate no significant learning curve associated with the technique.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arth.2007.05.032DOI Listing

Publication Analysis

Top Keywords

minimally invasive
12
cas combined
8
combined mis
8
mis tka
8
mechanical axis
8
degrees range
8
range degrees
8
degrees -93
8
-93 degrees
8
tourniquet time
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!