Cavity ringdown detection of losses in thin films in the telecommunication wavelength window.

Appl Opt

Science Technology Division, Corning, Incorporated, Sullivan Park, Corning, New York 14831-0000, USA.

Published: March 2001

The method of cavity ringdown spectroscopy (when a tunable pulsed optical parametric oscillator was used) was extended for the loss evaluation in thin films (2-20-microm thickness). The technique was applied in two key telecommunication wavelength ranges of 1260-1330 and 1480-1650 nm. The measurement sensitivity was determined to be 50 ppm (5 x 10(-5)). The results for polymer films are in close correlation with conventional spectrophotometric data and propagation loss for planar waveguides. Films of greater thickness and better optical quality are expected to provide an even higher loss resolution.

Download full-text PDF

Source
http://dx.doi.org/10.1364/ao.40.001570DOI Listing

Publication Analysis

Top Keywords

cavity ringdown
8
thin films
8
telecommunication wavelength
8
ringdown detection
4
detection losses
4
losses thin
4
films
4
films telecommunication
4
wavelength window
4
window method
4

Similar Publications

Absorption cross section of gas phase isoprene in the infrared-visible range.

Spectrochim Acta A Mol Biomol Spectrosc

January 2025

Department of Chemistry, University of Copenhagen, Universitetsparken 5, Copenhagen Ø, DK-2100, Denmark. Electronic address:

We have recorded the gas phase spectrum of isoprene at room temperature from the mid-infrared range and into the visible range (600 cm to 17050 cm). Absorption spectra were obtained by Fourier transform infrared, conventional dispersion ultraviolet-visible-near-infrared and cavity ring-down spectroscopy to cover the entire range with a resolution comparable to that of the instruments on the James Webb Space Telescope. We have assigned the CH-stretching fundamental and overtone bands corresponding to the Δv=1-6 transitions based on anharmonic vibrational calculations using normal mode and local mode models, for the lower- and higher-energy regions, respectively.

View Article and Find Full Text PDF

Cavity ring-down spectroscopy (CRDS) is rapidly becoming an invaluable tool to measure hydrogen (δ²H) and oxygen (δO) isotopic compositions in water, yet the long-term accuracy and precision of this technique remain relatively underreported. Here, we critically evaluate one-year performance of CRDS δ²H and δO measurements at ETH Zurich, focusing on high throughput (~200 samples per week) while maintaining required precision and accuracy for diverse scientific investigations. We detail a comprehensive methodological and calibration strategy to optimize CRDS reliability for continuous, high-throughput analysis using Picarro's "Express" mode, an area not extensively explored previously.

View Article and Find Full Text PDF

Ion Spectroscopy in the Context of the Diffuse Interstellar Bands: A Case Study with the Phenylacetylene Cation.

ACS Earth Space Chem

December 2024

School of Chemistry, The University of Edinburgh, Joseph Black Building, David Brewster Road, King's Buildings, Edinburgh EH9 3FJ, Scotland, U.K.

Identification of the molecular carriers of diffuse interstellar bands (DIBs) requires gas phase electronic spectra of suitable candidate structures. Recording the spectra of these in the laboratory is challenging because they include large, carbon-rich molecules, many of which are likely to be ionic. The electronic spectra of ions are often obtained using action spectroscopy methods, which can induce small perturbations to the absorption characteristics and hinder comparison with astronomical observations.

View Article and Find Full Text PDF

Radiocarbon analysis of nuclear waste produced in nuclear facilities lacks fast, in situ detection methods. Moreover, the amount of radiocarbon desorbing from graphitic waste is not well known. In this study, we demonstrate the use of mid-infrared cavity ring-down spectroscopy combined with an automatic sample processing unit as a method to examine radiocarbon concentration in three types of nuclear waste: spent ion-exchange resin, graphite, and graphite outgassing in sealed storage crates.

View Article and Find Full Text PDF

The radiative forcing caused by atmospheric aerosol represents one of the largest uncertainties in climate models. In part, these uncertainties derive from poor characterizations of the optical properties of light-absorbing brown carbon (BrC) containing aerosols. Here, single particle cavity ring-down spectroscopy (SP-CRDS) is used to determine the complex refractive index at the optical wavelength of 405 nm for aqueous particles composed of an abundant BrC species, 4-nitrocatechol.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!