A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Utilization of fluorescence tracer in hyperinsulinemic-euglycemic clamp test in mice. | LitMetric

Utilization of fluorescence tracer in hyperinsulinemic-euglycemic clamp test in mice.

J Biochem Biophys Methods

Institute of Materia Medica, Chinese Academy of Medical Sciences & Perking Union Medical College, 1, Xian Nong Tan Street, Beijing 100050, China.

Published: April 2008

The hyperinsulinemic-euglycemic clamp test is considered to be a gold standard for the evaluation of insulin sensitivity. Here, a new version of the clamp test that used the fluorescence tracer 2-NBDG was tested. C57BL/6J mice were induced insulin resistant (IR) with a high-calorie diet. Rosiglitazone was administrated to IR mice and diabetic db/db mice. Insulin resistance was estimated with the oral glucose tolerance test (OGTT), the insulin tolerance test (ITT), the serum insulin level and the homeostasis model assessment of insulin resistance (HOMA-IR), and then confirmed by the hyperinsulinemic-euglycemic clamp test with 2-NBDG. The 2-NBDG content was measured by the fluorescence intensity. The characteristics of insulin resistance were shown remarkably with the increased values of serum insulin and HOMA-IR in IR mice, and with the results from OGTT and ITT in both IR and db/db mice. In the hyperinsulinemic-euglycemic clamp test, the glucose infusion rate and amount of 2-NBDG taken up into the liver, adipose, and skeletal muscle were decreased significantly in IR mice and db/db mice, respectively. The clearing rates of 2-NBDG from the circulation were much slower in both mouse models. All markers were reversed significantly by rosiglitazone treatment. The results indicate that with the fluorescence tracer 2-NBDG, the hyperinsulinemic-euglycemic clamp test can be used to estimate insulin sensitivity in vivo.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jprot.2008.01.003DOI Listing

Publication Analysis

Top Keywords

clamp test
24
hyperinsulinemic-euglycemic clamp
20
fluorescence tracer
12
db/db mice
12
insulin resistance
12
insulin
9
test
8
mice
8
mice hyperinsulinemic-euglycemic
8
insulin sensitivity
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!