AI Article Synopsis

  • * The E-Scribe Warehouse, a part of this system available to sponsors, was tested using two data sets to evaluate the performance of its algorithms in determining electrocardiogram quality.
  • * Results showed that E-Scribe Warehouse effectively identified quality discrepancies between the tested datasets, confirming its capability to detect potential issues affecting QTc assessment in clinical trials.

Article Abstract

The US Food and Drug Administration recommends submission of digital electrocardiograms in the standard HL7 XML format into the electrocardiogram warehouse to support preapproval review of new drug applications. The Food and Drug Administration scrutinizes electrocardiogram quality by viewing the annotated waveforms and scoring electrocardiogram quality by the warehouse algorithms. Part of the Food and Drug Administration warehouse is commercially available to sponsors as the E-Scribe Warehouse. The authors tested the performance of E-Scribe Warehouse algorithms by quantifying electrocardiogram acquisition quality, adherence to QT annotation protocol, and T-wave signal strength in 2 data sets: "reference" (104 digital electrocardiograms from a phase I study with sotalol in 26 healthy subjects with QT annotations by computer-assisted manual adjustment) and "test" (the same electrocardiograms with an intentionally introduced predefined number of quality issues). The E-Scribe Warehouse correctly detected differences between the 2 sets expected from the number and pattern of errors in the "test" set (except for 1 subject with QT misannotated in different leads of serial electrocardiograms) and confirmed the absence of differences where none was expected. E-Scribe Warehouse scores below the threshold value identified individual electrocardiograms with questionable T-wave signal strength. The E-Scribe Warehouse showed satisfactory performance in detecting electrocardiogram quality issues that may impair reliability of QTc assessment in clinical trials in healthy subjects.

Download full-text PDF

Source
http://dx.doi.org/10.1177/0091270008316326DOI Listing

Publication Analysis

Top Keywords

e-scribe warehouse
24
quality issues
12
healthy subjects
12
food drug
12
drug administration
12
electrocardiogram quality
12
warehouse
9
performance e-scribe
8
digital electrocardiograms
8
warehouse algorithms
8

Similar Publications

The US Food and Drug Administration recommends submission of digital electrocardiograms in the standard HL7 XML format into the electrocardiogram warehouse to support preapproval review of new drug applications. The Food and Drug Administration scrutinizes electrocardiogram quality by viewing the annotated waveforms and scoring electrocardiogram quality by the warehouse algorithms. Part of the Food and Drug Administration warehouse is commercially available to sponsors as the E-Scribe Warehouse.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!

A PHP Error was encountered

Severity: Notice

Message: fwrite(): Write of 34 bytes failed with errno=28 No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 272

Backtrace:

A PHP Error was encountered

Severity: Warning

Message: session_write_close(): Failed to write session data using user defined save handler. (session.save_path: /var/lib/php/sessions)

Filename: Unknown

Line Number: 0

Backtrace: