Background: In this study we quantified and compared the optimal sevoflurane concentration required to prevent coughing or moving during or after removal of the laryngeal mask airway (LMA) and the laryngeal tube (LT) in anesthetized children.

Methods: Forty unpremedicated children, aged 8 mo to 12 yr, were randomly allocated to receive the LMA or LT. General anesthesia was induced via mask with sevoflurane and the LMA or LT was inserted. Anesthesia was maintained with sevoflurane and oxygen. At the end of surgery, a predetermined end-tidal sevoflurane concentration was maintained for at least 10 min and the LMA or LT was removed. Using Dixon's up-down method, the concentration for LMA and LT removal was determined by adjusting the dose by a 0.2% increment. Success was defined by the absence of coughing, teeth clenching, gross purposeful movement, breath holding, laryngospasm, and desaturation.

Results: The end-tidal concentration of sevoflurane to achieve successful LMA removal in 50% of children was 1.90%, in 95% of children was 2.15%. For the LT, the concentrations were 1.83% and 2.00%. The 50% effective dose values did not differ significantly between groups.

Conclusions: LMA and LT removal in 95% of anesthetized children (aged 8 mo to 12 yr) can be safely accomplished without coughing, moving, or any other airway complications at 0.86 and 0.80 minimum alveolar anesthetic concentration, respectively, and a similar concentration should be used for removal of the LT or LMA in children.

Download full-text PDF

Source
http://dx.doi.org/10.1213/01.ane.0000286174.07844.e9DOI Listing

Publication Analysis

Top Keywords

sevoflurane concentration
12
lma removal
12
end-tidal sevoflurane
8
concentration removal
8
removal laryngeal
8
laryngeal mask
8
mask airway
8
laryngeal tube
8
tube anesthetized
8
anesthetized children
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!