A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A microarray chip for label-free detection of narcotics. | LitMetric

A microarray chip for label-free detection of narcotics.

Anal Bioanal Chem

Division of Molecular Physics, Department of Physics, Chemistry and Biology, Linköping University, 581 83, Linköping, Sweden.

Published: July 2008

A protein array chip for label-free optical detection of low molecular weight compounds has been developed. As a proof of principle, the chip is proven capable of rapidly (approximately 1 min) determining hits from aqueous cocktails composed of four common narcotics, cocaine, ecstasy, heroin, and amphetamine, using imaging surface plasmon resonance (SPR) as the detection principle. The chip is produced by injecting a mixture of antibodies and letting them self-sort and bind to narcotic analog coupled proteins already present in a predefined pattern on the supporting substrate. An indirect detection method, where antibodies are displaced from the surface upon recognition of their corresponding narcotics, is used to obtain the optical contrast and thus a detectable SPR and/or ellipsometric signal. Two types of readouts are possible from the present setup: intensity SPR images and SPR/ellipsometric sensorgrams. Positive hits were routinely obtained for analyte concentrations of 50 pg/microL and the limit of detection, without any parameter optimizations, seems to fall in the range 0.5 pg/microL (1.4 nM) for heroin, 2.5 pg/microL (8.2 nM) for cocaine, and 5 pg/microL for the other two narcotics (26 nM for ecstasy and 37 nM for amphetamine). With improved readout possibilities (sampling frequency), signal evaluation algorithms, and antibody-antigen design strategies, we believe this limit can be further improved. The chip is shown to work for many measurement cycles with excellent reproducibility. Moreover, with a more advanced fluidic system, excess injected antibodies could be collected and reused for many cycles, which could make the running costs of the system very low. The chip is in no way limited to detection of narcotics. Other low molecular weight compounds could easily be detected on the same chip. For example, trinitrotoluene detection has already been demonstrated using our chip. Possible areas of application for the system are therefore envisaged in airport and underground transport security, customs, drug interdiction, forensics, and as warning alerts on military equipment and personnel.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00216-008-1839-9DOI Listing

Publication Analysis

Top Keywords

chip label-free
8
detection narcotics
8
low molecular
8
molecular weight
8
weight compounds
8
principle chip
8
detection
7
chip
7
narcotics
5
microarray chip
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!