A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effects of different suture materials on cartilage reshaping. | LitMetric

Objective: To examine the effects of different suture materials and suturation techniques on cartilage reshaping in a rabbit model.

Methods: Twenty-two rabbits were used. Posterior skin flaps were elevated, and 4 cartilage struts were prepared on each auricula. Each strut was bent at its midpoint, and the skin under the bent area was elevated only in 1 side. The strut was sutured either with catgut, polyglactin 910, polydioxanone, or polypropylene sutures. Anteriorly, the suture was passed subcutaneously on 1 side, while transcutaneously on the other. Animals were killed at the first and fourth months. The shape of the struts was macroscopically evaluated. Inflammation and foreign body reaction around the suture were examined under light microscopy.

Results: Maintenance of shape with all suture materials was significantly lower in the transcutaneously sutured group than in the subcutaneously sutured group. Because of high rates of suture loss in the transcutaneously sutured group, further evaluations on cartilage tissue were made only in subcutaneously sutured group. Success rate in maintenance of shape was similarly high in the polydioxanone, polyglactin 910, and polypropylene suture groups; however, it was significantly lower in the catgut suture group.

Conclusion: Long-lasting absorbable suture materials are as effective as nonabsorbable ones, and the subcutaneous technique is more effective than the transcutaneous technique.

Download full-text PDF

Source
http://dx.doi.org/10.1001/archfaci.10.2.124DOI Listing

Publication Analysis

Top Keywords

suture materials
16
sutured group
16
effects suture
8
cartilage reshaping
8
suture
8
polyglactin 910
8
maintenance shape
8
transcutaneously sutured
8
subcutaneously sutured
8
sutured
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!