A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Microwave ablation in a hepatic porcine model: correlation of CT and histopathologic findings. | LitMetric

Microwave ablation in a hepatic porcine model: correlation of CT and histopathologic findings.

HPB (Oxford)

Department of Surgery, Johns Hopkins Medical Institutions, Baltimore, MD 21287, USA.

Published: May 2010

Background: Thermal ablative techniques have gained increasing popularity in recent years as safe and effective options for patients with unresectable solid malignancies. Microwave ablation has emerged as a relatively new technique with the promise of larger and faster burns without some of the limitations of radiofrequency ablation (RFA). Here we study a new microwave ablation device in a living porcine model using gross, histologic, and radiographic analysis.

Materials And Methods: The size and shape of ablated lesions were assessed using six pigs in a non-survival study. Liver tissue was ablated using 2, 4, and 8 min burns, in both peripheral and central locations, with and without vascular inflow occlusion. To characterize the post-ablation appearance, three additional pigs underwent several 4 min ablations each followed by serial computed tomography (CT) imaging at 7, 14, and 28 days postoperatively.

Results: The 2 and 4 min ablations resulted in lesions that were similar in size, 33.5 cm(3) and 37.5 cm(3), respectively. Ablations lasting 8 min produced lesions that were significantly larger, 92.0 cm(3) on average. Proximity to hepatic vasculature and inflow occlusion did not significantly change lesion size or shape. In follow-up studies, CT imaging showed a gradual reduction in lesion volume over 28 days to 25-50% of the original volume.

Discussion: Microwave ablation with a novel device results in consistently sized and shaped lesions. Importantly, we did not observe any significant heat-sink effect using this device, a major difference from RFA techniques. This system offers a viable alternative for creating fast, large ablation volumes for treatment in liver cancer.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2225513PMC
http://dx.doi.org/10.1080/13651820701646222DOI Listing

Publication Analysis

Top Keywords

microwave ablation
16
porcine model
8
size shape
8
inflow occlusion
8
min ablations
8
ablation
5
microwave
4
ablation hepatic
4
hepatic porcine
4
model correlation
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!