Purpose: To determine retinal nerve fiber layer (RNFL) thickness measurements in normal, ocular hypertensive (OHT), and glaucomatous Asian Indian eyes.

Methods: This prospective observational cross-sectional study included patients with OHT, primary open angle glaucoma (POAG), and age-matched normal controls. The global and 4-quadrant average RNFL thickness was measured using the Stratus OCT. The main outcome measures were differences in RNFL thickness measurements between the 3 groups. The discriminating power of each parameter was evaluated by calculating areas under receiver operating characteristic curves (AROCs).

Results: Twenty-three eyes of 23 POAG patients, 24 eyes of 24 OHT, and 48 eyes of 48 normal controls were analyzed. The superior, inferior, and global RNFL measurements were significantly thinner in OHTs compared with normals (P=0.031, 0.019, and 0.022, respectively). All 5 RNFL parameters were significantly thinner in the POAG group compared with OHT group (P<0.001). Parameters with largest AROCs for distinguishing glaucoma from OHT were average and inferior average RNFL measurements (0.989 and 0.979, respectively). Inferior and superior RNFL measurements had largest AROCs (0.717 and 0.700, respectively) to distinguish OHT from normal eyes.

Conclusions: Stratus OCT detected significant quantitative differences in RNFL thickness between normal, OHT, and glaucomatous Asian Indian eyes.

Download full-text PDF

Source
http://dx.doi.org/10.1097/IJG.0b013e31814b9817DOI Listing

Publication Analysis

Top Keywords

rnfl thickness
12
retinal nerve
8
nerve fiber
8
fiber layer
8
normal ocular
8
ocular hypertensive
8
thickness measurements
8
normal controls
8
rnfl
5
thickness
4

Similar Publications

Background/ Aims: To analyze the longitudinal change in Bruch's membrane opening minimal rim width (BMO-MRW) and peripapillary retinal nerve fiber layer (pRNFL) thickness using optical coherence tomography (OCT) after implantation of a PRESERFLO® microshunt for surgical glaucoma management in adult glaucoma patients.

Methods: Retrospective data analysis of 59 eyes of 59 participants undergoing implantation of a PRESERFLO microshunt between 2019 and 2022 at a tertiary center for glaucoma management. Surgical management included primary temporary occlusion of the glaucoma shunt to prevent early hypotony.

View Article and Find Full Text PDF

The impact of various neurodegenerative diseases on the retina has been investigated in recent years using optical coherence tomography (OCT). Epilepsy, classified as a neurodegenerative disorder, has been indicated to affect the structural integrity of the retina. Moreover, there is ongoing debate regarding the relative contribution of disease pathogenesis and the consumption of anti-epileptic drugs (AEDs) to these retinal changes.

View Article and Find Full Text PDF

Study Objectives: To assess the effect of continuous positive airway pressure (CPAP) therapy on intraocular pressure in Obstructive sleep apnea (OSA) patients.

Methods: The search was performed in Ovid Medline and Embase database then followed by a manual bibliography search. Abstract search and screening were independently performed followed by eligible full-text versions reviewed.

View Article and Find Full Text PDF

Anatomy-driven segmentation of parafoveal optical coherence tomography (OCT) measures may improve associations with clinical outcomes in multiple sclerosis.

J Neurol

January 2025

Jacobs Comprehensive MS Treatment and Research Center, Department of Neurology, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, State University of New York, Buffalo, NY, USA.

Background: Previous investigations on optical coherence tomography (OCT) in multiple sclerosis (MS) focused on generalizable macular and peri-papillary regions without considering the anatomic variations of the retinal layer thickness.

Objective: This study aimed to assess the utility of parafoveal retinal layer thickness measured by OCT, underscoring its relationships with clinical outcomes in MS.

Methods: In this cross-sectional study, 214 people with MS (pwMS) and 57 age- and sex-matched healthy controls (HCs) were enrolled.

View Article and Find Full Text PDF

Purpose: To identify the macular retinal layer thickness changes in polyarteritis nodosa (PAN) patients without pathological findings appearing in color fundus photography (CFP), and to investigate the correlations with disease durations.

Methods: A total of 24 PAN patients who had been for 3 years or more and underwent SD-OCT were recruited from the UK Biobank, with exclusions for diabetes, eye disease, or abnormal CFP findings. Only the right eyes were included, with each PAN patient paired one-to-one with a control matched for age, sex, and ethnicity.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!