Purpose: It is known that macula can be affected adversely in glaucoma. In this study, we aimed to evaluate the functional and morphologic changes of macula in patients having glaucoma using Microperimeter-1 (MP-1), Humphrey field analyzer (HFA), and Heidelberg Retina Tomograph II (HRT-II).
Materials And Methods: This prospective study consisted of 43 patients having primary open angle glaucoma. Control group consisted of 26 normal cases. Macular threshold was evaluated with HFA macula threshold test and MP-1 Humphrey macula pattern. Morphometric evaluation of macula was performed with HRT-II. The results were evaluated by independent samples t test and receiver operator curves.
Results: Macular sensitivity was lower in patients having glaucoma with both HFA and MP-1 in all quadrants (P=0.003 for HFA and P=0.002 for MP-1). The macular thickness measurements obtained with HRT-II was not significant between glaucoma patients and control group (P=0.153). The difference between HFA and MP-1, HFA and HRT-II, MP-1 and HRT-II was not statistically significant (P=0.302, 0.110, and 0.481, respectively).
Conclusions: Perimetric macular changes can occur while macular topographic remains stable in patients with glaucoma. MP-1 correlates with HFA in detecting glaucomatous visual field defect in macular area.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/IJG.0b013e31814b97fd | DOI Listing |
Clin Exp Optom
January 2025
Department of Ophthalmology, Dünyagöz Tunus Hospital, Ankara, Türkiye.
Clinical Relevance: Pseudoexfoliation syndrome (PXS) is a common age-related disorder associated with glaucoma and cataract. Despite its clinical importance, the pathogenesis of PXS is not yet fully understood.
Background: To evaluate levels of SCUBE-1 (signal peptide, CUB domain, and epidermal growth factor-like domain containing protein 1) in the serum and aqueous humour of patients with PXS in comparison with non-PXS controls.
Fluids Barriers CNS
January 2025
Department of Neurosurgery, Osaka Medical and Pharmaceutical University, Takatsuki, Osaka, Japan.
Background: Cerebral autoregulation is a robust regulatory mechanism that stabilizes cerebral blood flow in response to reduced blood pressure, thereby preventing cerebral ischaemia. Scientists have long believed that cerebral autoregulation also stabilizes cerebral blood flow against increases in intracranial pressure, which is another component that determines cerebral perfusion pressure. However, this idea was inconsistent with the complex pathogenesis of normal pressure hydrocephalus, which includes components of chronic cerebral ischaemia due to mild increases in intracranial pressure.
View Article and Find Full Text PDFBr J Ophthalmol
January 2025
Department of Ophthalmology, Severance Hospital, Institute of Vision Research, Yonsei University College of Medicine, Seoul, Seodaemun-gu, Korea (the Republic of)
Background: The present study aims to identify the relationship between longitudinal changes in corneal hysteresis (CH) and progressive retinal nerve fibre layer (RNFL) thinning in a cohort of medically controlled, early-to-moderate open-angle glaucoma (OAG) patients with a history of laser refractive surgery (LRS).
Methods: A total of 123 consecutive eyes with a diagnosis of medically controlled (peak intraocular pressure (IOP)<18 mm Hg), early-to-moderate OAG with a history of LRS underwent measurements of CH, corneal-compensated intraocular pressure (IOPcc) and RNFL thicknesses every 6 months. Linear models were used to investigate the relationship between CH change and RNFL thickness change over time.
Asia Pac J Ophthalmol (Phila)
January 2025
State Key Laboratory of Ophthalmology, Guangzhou, China; Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China; Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangzhou, China. Electronic address:
To analyze the treatment modalities and trends for neovascular glaucoma (NVG) over the past 10 years, we conducted a retrospective analysis at Zhongshan Ophthalmic Center on 1331 NVG inpatients who received 1459 treatments for 1383 eyes between January 1, 2012, and December 31, 2021. Over time, we observed a progressive annual increase in both the number of patients and the volume of surgeries for NVG, with an annual percentage change (APC) of 10.23% (95% confidence interval [CI]: 5.
View Article and Find Full Text PDFRetina
January 2025
Department of Ophthalmology, Harvard Medical School, Boston, MA, USA.
Purpose: To describe effects of sustained-release steroid delivery devices on intraocular pressure (IOP) in eyes with glaucoma drainage devices (GDD).
Methods: Retrospective case series of eyes with steroid implants (dexamethasone or fluocinolone acetonide) and prior GDD (Ahmed, Baerveldt) without uveitis. Outcomes included IOP, IOP rise, central foveal thickness (CFT), and IOP medications.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!