Three-dimensional architecture of membrane-embedded MscS in the closed conformation.

J Mol Biol

Department of Molecular Physiology and Biological Physics, University of Virginia, Charlottesville, VA 22908, USA.

Published: April 2008

AI Article Synopsis

Article Abstract

The mechanosensitive channel of small conductance (MscS) is part of a coordinated response to osmotic challenges in Escherichia coli. MscS opens as a result of membrane tension changes, thereby releasing small solutes and effectively acting as an osmotic safety valve. Both the functional state depicted by its crystal structure and its gating mechanism remain unclear. Here, we combine site-directed spin labeling, electron paramagnetic resonance spectroscopy, and molecular dynamics simulations with novel energy restraints based on experimental electron paramagnetic resonance data to investigate the native transmembrane (TM) and periplasmic molecular architecture of closed MscS in a lipid bilayer. In the closed conformation, MscS shows a more compact TM domain than in the crystal structure, characterized by a realignment of the TM segments towards the normal of the membrane. The previously unresolved NH(2)-terminus forms a short helical hairpin capping the extracellular ends of TM1 and TM2 and is in close interaction with the bilayer interface. The present three-dimensional model of membrane-embedded MscS in the closed state represents a key step in determining the molecular mechanism of MscS gating.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2703500PMC
http://dx.doi.org/10.1016/j.jmb.2007.10.086DOI Listing

Publication Analysis

Top Keywords

membrane-embedded mscs
8
mscs closed
8
closed conformation
8
crystal structure
8
electron paramagnetic
8
paramagnetic resonance
8
mscs
7
three-dimensional architecture
4
architecture membrane-embedded
4
closed
4

Similar Publications

Three-dimensional architecture of membrane-embedded MscS in the closed conformation.

J Mol Biol

April 2008

Department of Molecular Physiology and Biological Physics, University of Virginia, Charlottesville, VA 22908, USA.

The mechanosensitive channel of small conductance (MscS) is part of a coordinated response to osmotic challenges in Escherichia coli. MscS opens as a result of membrane tension changes, thereby releasing small solutes and effectively acting as an osmotic safety valve. Both the functional state depicted by its crystal structure and its gating mechanism remain unclear.

View Article and Find Full Text PDF

Crystal structure of Escherichia coli MscS, a voltage-modulated and mechanosensitive channel.

Science

November 2002

Division of Chemistry and Chemical Engineering, Biochemistry Option, Howard Hughes Medical Institute, Mail Code 114-96, California Institute of Technology, Pasadena, CA 91125, USA.

The mechanosensitive channel of small conductance (MscS) responds both to stretching of the cell membrane and to membrane depolarization. The crystal structure at 3.9 angstroms resolution demonstrates that Escherichia coli MscS folds as a membrane-spanning heptamer with a large cytoplasmic region.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!